Mineral insulated cable type k,j,t,e thermocouple mi cable
Description:
Features
Mineral Insulated Thermocouple Cable
Temperature range:-200-1300
MI cable: OD 0.25 - 8.00
Sheath material: Inconel 600, SS316, SS304, SS321.
Mini coil length: Per client's request
Accuracy: Class I, II
Wire: Simplex & duplex
Electric property:
Resistance value allowance:±10%
Dielectric property:heating cable pressure resist:1200V AC/1min
Insulation resistance:end product test:100MΩ/500VDC
Sheath continuity:all the heating cable submerged in the water 12 hours then test the insulation resistance,the value should be 50M/500VDC at least.