Traction 1.5m/s Machine Room Passenger Elevator For Hotel Shopping Center Office Building with Non-touch Button LCD COP
1. TISCHBEIN is focusing on the global elevator development and manufacturing for many years. The company is a manufacturer integrating product development, design, manufacturing, sales, installation and maintenance. Our product scope covers passenger elevators, panoramic elevators, hospital elevators, freight elevators, automobile elevators, home elevators, escalators, moving walkway, wheelchair lift, etc.
2. Production introduction:
Capacity(kg) | Speed (m/s) | Control mode | Cabin size (mm) | Door size (mm) | Hoistway(mm) | Machine Room (mm) | ||||||||
C.W | C.D | C.H | D.H | H.W | H.W | H.D | P.H | HR.H | MR.W | MR.D | MR.H | |||
450 | 1 | VVVF | 1100 | 1000 | 2500 | 800 | 2100 | 1850 | 1700 | 1500 | 4500 | 2500 | 3300 | 2500 |
1.75 | 1700 | 4800 | ||||||||||||
630 | 1 | 1400 | 1100 | 2500 | 800 | 2100 | 2000 | 1800 | 1500 | 4500 | 2500 | 3300 | 2500 | |
1.75 | 1700 | 4800 | ||||||||||||
800 | 1 | 1400 | 1350 | 2500 | 800 | 2100 | 2000 | 2000 | 1500 | 4500 | 2600 | 3650 | 2500 | |
1.75 | 1700 | 4800 | ||||||||||||
2 | 1900 | 5100 | ||||||||||||
2.5 | 2100 | 5300 | ||||||||||||
1000 | 1 | 1600 | 1500 | 2500 | 900 | 2100 | 2200 | 2200 | 1500 | 4500 | 2800 | 3850 | 2500 | |
1.75 | 1700 | 4800 | ||||||||||||
2 | 1900 | 5100 | ||||||||||||
2.5 | 2100 | 5300 | ||||||||||||
1150 | 1 | 1800 | 1500 | 2500 | 1100 | 2100 | 2400 | 2200 | 1500 | 4500 | 3200 | 3850 | 2500 | |
1.75 | 1700 | 4800 | ||||||||||||
2 | 1900 | 5100 | ||||||||||||
2.5 | 2100 | 5300 | ||||||||||||
1350 | 1 | 1900 | 1600 | 2500 | 1100 | 2100 | 2500 | 2300 | 1500 | 4500 | 3250 | 3950 | 2500 | |
1.75 | 1700 | 4800 | ||||||||||||
2 | 1900 | 5100 | ||||||||||||
2.5 | 2100 | 5300 | ||||||||||||
1600 | 1 | 2000 | 1750 | 2500 | 1100 | 2100 | 2600 | 2500 | 1500 | 4500 | 3250 | 4150 | 2500 | |
1.75 | 1700 | 4800 | ||||||||||||
2 | 1900 | 5100 | ||||||||||||
2.5 | 2100 | 5300 |
3.
4. Standard Function:
Standard Function: | |
Automatic operation | The lift automatically runs and stops, opens/shuts the door according to designated command |
Operation by operator | The lift automatically runs and stops, manually shuts the door according to designated command |
Overhaul operation | Under repair and inspection conditions, the lift runs at inspection speed through operating ‘slow up/slowdown’ buttons. |
Upper automatic door-opening | When the lift is electrified and the car is in the door zone, it will open the door automatically |
Automatic door-shut time-delay | After the car door has been opened completely, it keeps the door open condition, It automatically shuts the door after time-delay |
Call for opening of this floor | When the lift is shutting the door or it does not start but has closed the door, when there is any outer calling from this landing, it wil reopen the door. |
Optical curtain protection | When light curtain is hindered, it immediately stops door-shut action and automatically opens the door. |
Over-load none door-shut | It does not shut the door in overload, And it is bright from overload lamp, The buzzer rings, It shows CZ or overload in the car and does not start the lift. |
Full-load direct running | When it reaches the rated load, it only responds to internal selection instead of outer calling. |
Automatic lighting& fan control | In the stipulated time, if the lift does not receive any travel command, the lighting will automatically die out, It automatically opens at command. |
Contact or protection | The system can detect whether motor circuit contact or action is reliable or no, If any abnorm a condition happens,it wil stop the lift travel |
Main contact or protection | After the lift executes door-shut command, if the door has not been closed within the stipulated time, it wil re-open the door and then shut it again |
Landing floor, direction display in the car | It shows the landing floor of the lift, the direction where the lift is going to travel in the car. |
Direction chosen by driver | The running direction is determined by the driver's directive. |
Trouble diagnosis | When there is something wrong in the travel process, it will automatically diagnose the trouble cause, display in the operation panel and automatically store the latest trouble information. |
Door interlocking protection | If it closes all of door interlocking, it can then start the lift, If door interlocking is disconnected or trembled, the lift will stop the operation. |
Brake test protection | It implement real-time monitor to the brake open/shut through brake arm test switch, If the brake has been opened improperly, the system wll not allow the lift to start |
Terminal speed change and landing floor number correction | After the system detect fermin al switch in travel, the lift will be forced to change the speed and automati-cally correct the landing floor display. |
Position-Limit protection | If the system detects limit switch action,it will immediately stop the lift travel |
Limit protection | If the system detects limit switch action,the whole system will immediately lose power. |
Over-speed protection | When the lift up/down exceeds 1.2 times of the rated speed, it will cutoff control mains and stop the lift travel. |
5. Packing and Shipment:
TISCHBEIN ELEVATOR, TIED TO SAFETY. And welcome to contact us!