UL21088 Non-silicone Flexible FRPE Sheathed Fireproof LSZH Cable
Conductor: High Purity of Copper Wire, Stranded or Solid.
Insulation: HDPE, XLPE, FRPE, PP
Jacket: Extruded FRPE / LSZH material
Rated Temperature: 60C or 80C
Rated Voltage: 30V
Flame Retardant Grade: VW-1, FT-1, FT-2
Executed Standard: Appliance Wiring Material UL 758.
Application: Internal wiring of appliances and external interconnection of electronic equipment.
Parameters of UL21088 Non-silicone Flexible FRPE Sheathed Fireproof LSZH Cable:
Approval Style Number | Cores | Conductor | Insulation Thickness | Nom.Dia | Shield Coverage | Jacket Thickness | Overall Diameter | Conductor Resistance | |
AWG | No/mm | mm | mm | % | mm | mm | Ω/KM | ||
UL21088 | 2C | 28 | 7/0.127 | 0.4 | 1.20 | 32/0.12 | 0.40 | 2.5×5.0 | 239.00 |
26 | 7/0.16 | 0.4 | 1.30 | 33/0.12 | 0.40 | 2.6×5.2 | 150.00 | ||
24 | 11/0.16 | 0.4 | 1.50 | 37/0.12 | 0.40 | 2.7×5.4 | 94.20 | ||
22 | 17/0.16 | 0.4 | 1.70 | 42/0.12 | 0.40 | 3.0×6.0 | 59.40 | ||
UL21088 | 3C | 28 | 7/0.127 | 0.4 | 1.20 | 30/0.12 | 0.40 | 2.5×7.5 | 239.00 |
26 | 7/0.16 | 0.4 | 1.30 | 33/0.12 | 0.40 | 2.6×7.8 | 150.00 |