Specifications
Brand Name :
RISING
Model Number :
RSBTT III
Certification :
ISO CE
Place of Origin :
China
MOQ :
1 Set
Payment Terms :
T/T, Western Union, MoneyGram,L/C, D/A, D/P,
Supply Ability :
100 SET PER Month
Delivery Time :
20 working days
Packaging Details :
Wooden package for export
Voltage :
0.1-800V
Current :
0.1-300A
Power :
U*I
Power factor :
0.1-0.9999
Power supply :
AC380V±10% 50Hz±2%
Working temperature :
0-40℃
Relative humidity :
30%-90%
Outline dimension :
Customization
Description

Full Automatic Transformer Testing Equipment No-load and Load Loss Test Transformer Test Panel Test board

IEC 60076

Product Description
Introduction of system composing and technical parameters
1 To satisfy three-phase, one-phase measurement, transformer no-load and load should come to the following requirements:
Voltage measuring range: 0~650V, current measuring range: 10mA~2A,
Accuracy: 0.2 class; power: U*I, Accuracy: 0.2 class;
Power factor: 0.050~1.000,accuracy: 0.2 class;
Frequency: 40—70Hz, accuracy: 0.1 class; three-phase total power P;
No-load current I.%,No-load loss P.;
Load loss PK,impedance voltage UK;
Three frequency Pa(Pab),Pb,Pc(Pbc);
Average three-phase line voltage Un;
Average three-phase current In. (including 19 harmonic wave analysis)
2. High-voltage precision current transformer should meet
the following requirements:
Rated operation voltage: 3kV
Withstand voltage:4kV
Capacity: 1VA
Measuring range: 0.1A~200A;
Accuracy: 0.05 class
The ratios are 200A,100A,50A,25A,10A,5A,2.5A/1A, total 7 steps.
3. High precision Voltage transformer should meet the
following requirements:
Rated operation voltage: 3kV
Withstand voltage: 4kV
Capacity: 1VA
Measuring range: 0.01kV~3kV;
Accuracy: 0.05 class;
The ratios are 3kV,2kV,1kV,0.5kV/0.1kV, total 4 steps. 7
4. 250kVA three-phase voltage regulator should meet the
following requirements:
Capacity;250kVA
Input voltage:380V
Output voltage:20-650V
Max load current: 222A
When the input voltage is steady,the voltage regulator can stepless and smoothly adjust the output voltage.
Technical Parameters:
Item
Scope of Measurement
Relative Error
Voltage
0.1-800V
±(0.2% reading + 0.1% range)
Current
0.1-300A
±(0.2% reading + 0.1% range)
Power
U*I
±(0.2% reading + 0.1% range)
Power factor
0.1-0.9999
±3 figures
Power supply
AC 380V±10% 50Hz±2%
Operating condition
Working temperature: -20℃-40℃ Relative humidity <90%
Outline dimension
Customization
Weight
Customization
Send your message to this supplier
Send Now

No Load And Load Loss Test Transformer Test Bench IEC 60076 Standard

Ask Latest Price
Watch Video
Brand Name :
RISING
Model Number :
RSBTT III
Certification :
ISO CE
Place of Origin :
China
MOQ :
1 Set
Payment Terms :
T/T, Western Union, MoneyGram,L/C, D/A, D/P,
Contact Supplier
video
No Load And Load Loss Test Transformer Test Bench IEC 60076 Standard

Wuhan Rising Electric Co., Ltd.

Active Member
6 Years
hubei, wuhan
Since 2006
Business Type :
Manufacturer, Trading Company
Certification Level :
Active Member
Contact Supplier
Submit Requirement