15kV DC Insulation Resistance Tester
Model: HIT-15
The Insulation Resistance test is a quantitative test, which indicates the effectiveness of a product’s electrical insulation. The main applications include cables, transformers, motors / generators, circuit breakers and bushings.
The HIT-15 is designed for performing insulation resistance tests up to 15 kV with a
50 TΩ maximum resistance. The HIT-15 offers DAR(Dielectric Absorption Ratio) and PI(Polarization Index) measurement.
The HIT-15 is capable of measuring capacitance of test object from 10uf to 100nf.
12V rechargeable Li-ion battery is adopted for HIT-15, which offers rapid charge from an AC source if the batteries are flat.
The HIT-15 has a full suite of test modes as well as on-board memory and the ability to download data to a laptop.
IP54 weatherproof enclosure is designed for outdoor operation. The HIT-15 unit is robust enough to protect the tester and eliminate moisture and dust ingress.
Main Features
1) Insulation resistance up to 50 TΩ @ 15 kV
2) Rated voltage: 500V, 1kV, 2.5kV, 5kV,10kV,15kV
3) AC voltage range: 0-750V
4) DC voltage range: 0-1000V
5) Measures capacitance of test object
6) Measures DAR(Dielectric Absorption Ratio) and PI(Polarization Index)
7) High current 6mA short circuit current output
8) Large LCD display with backlight
9) Advanced memory and on screen recall
10) Download of on-board results via USB interface
11) IP54 weatherproof enclosure
12) Safety rated at CAT Ⅲ 300V
Technical Data
Function | insulation resistance test, voltage test |
Base Conditions | 23°C±5°C, below 75%RH |
Rated Voltage(V) | 500V, 1kV, 2.5kV, 5kV,10kV,15kV |
Test Voltage(V) | rated voltage x(1±10%) |
Insulation Resistance Range | 0.01MΩ~50TΩ |
Insulation Resistance Resolution | 0.01MΩ |
DC Voltage Range | 0~1000V |
DC Voltage Resolution | 0.1V |
AC Voltage Range | 0~750V |
AC Voltage resolution | 0.1V |
Output Short-circuit Current | ≥6mA |
Dielectric Absorption Ratio and Polarization Index Measurement | available |
Power Supply | 12V rechargeable battery |
Backlight | controllable gray screen backlight, suitable for use in dim places |
Display Mode | 4-bit large LCD display, gray screen backlight |
LCD Display Size | 108×65mm |
Instrument Size | 277.2×227.5×153mm(LxWxH) |
USB Interface | for software monitoring and data transmission. The saved data can be uploaded to the computer for save and print. |
Communication Line | USB communication line 1pc |
Test Line | high voltage rob red 3 meters, high voltage test line black 1.5smeters, green 1.5 meters |
Data Storage | 500 groups. "FULL" symbol indicates that storage is full. |
Data View | data view function: "MR" symbol display |
Overflow Display | overflow function(exceed measurement range): “OL ” symbol display |
Alarm Function | when the measured value exceeds the set value, an alarm prompt will be given |
Power Consumption | standby: max.30mA(backlight off) |
turn on backlight: max.42mA | |
measure. max.300mA(backlight off) | |
Instrument weight | 2.75kg(including battery) |
Battery voltage | when the battery voltage is low, low battery symbol will display. |
Automatic shut-down | automatic shutdown after 15 minutes boot |
Insulation Test | ≥50MΩ(between measuring line and case) |
Withstand Voltage | AC3kV/50Hz, 1min |
Working Temperature and Humidity | -10℃~+50℃<85%RH |
Storage Temperature and Humidity | -15℃~+55℃<90%RH |
Safety | IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54) pollution grade II, CAT Ⅲ 300V |
Insulation Resistance Measuring Range and Accuracy
Measuring Function | Output voltage | Measuring Range | Accuracy | Resolution |
Insulation Resistance |
500V(±10%)
|
0 MΩ~2MΩ | ±5%rdg±5dgt | 0.001MΩ |
2 MΩ~20MΩ | ±5%rdg±5dgt | 0.01MΩ | ||
20 MΩ~200MΩ | ±5%rdg±5dgt | 0.1MΩ | ||
200 MΩ~2000MΩ | ±5%rdg±5dgt | 1MΩ | ||
2GΩ~20GΩ | ±5%rdg±5dgt | 0.01GΩ | ||
20GΩ~200GΩ | ±10%rdg±5dgt | 0.1GΩ | ||
200GΩ~2000GΩ | ±20%rdg±5dgt | 1GΩ | ||
1kV(±10%) | 0 MΩ~5MΩ | ±5%rdg±5dgt | 0.001MΩ | |
5 MΩ~50MΩ | ±5%rdg±5dgt | 0.01MΩ | ||
50 MΩ~500MΩ | ±5%rdg±5dgt | 0.1MΩ | ||
500 MΩ~5000MΩ | ±5%rdg±5dgt | 1MΩ | ||
5GΩ~50GΩ | ±10%rdg±5dgt | 0.01GΩ | ||
50GΩ~500GΩ | ±15%rdg±5dgt | 0.1GΩ | ||
500GΩ~5000GΩ | ±20%rdg±5dgt | 1GΩ | ||
2.5kV(±10%) | 0 MΩ~10MΩ | ±5%rdg±5dgt | 0.01MΩ | |
10 MΩ~100MΩ | ±5%rdg±5dgt | 0.1MΩ | ||
100 MΩ~1000MΩ | ±5%rdg±5dgt | 1MΩ | ||
1 GΩ~10GΩ | ±5%rdg±5dgt | 0.01GΩ | ||
10 GΩ~100GΩ | ±10%rdg±5dgt | 0.1GΩ | ||
100 GΩ~1000GΩ | ±15%rdg±5dgt | 1GΩ | ||
1 TΩ~10TΩ | ±20%rdg±10dgt | 0.01TΩ | ||
5kV(±10%) | 0 MΩ~20MΩ | ±5%rdg±5dgt | 0.01MΩ | |
20 MΩ~200MΩ | ±5%rdg±5dgt | 0.1MΩ | ||
200 MΩ~2000MΩ | ±5%rdg±5dgt | 1MΩ | ||
2 GΩ~20GΩ | ±5%rdg±5dgt | 0.01GΩ | ||
20 GΩ~200GΩ | ±10%rdg±5dgt | 0.1GΩ | ||
200 GΩ~2000GΩ | ±15%rdg±5dgt | 1GΩ | ||
2 TΩ~10TΩ | ±25%rdg±10dgt | 0.01TΩ | ||
10KV(±10%) | 0 MΩ~50MΩ | ±5%rdg±5dgt | 0.01MΩ | |
50 MΩ~500MΩ | ±5%rdg±5dgt | 0.1MΩ | ||
500 MΩ~5000MΩ | ±5%rdg±5dgt | 1MΩ | ||
5 GΩ~50GΩ | ±5%rdg±5dgt | 0.01GΩ | ||
50 GΩ~500GΩ | ±10%rdg±5dgt | 0.1GΩ | ||
500 GΩ~5000GΩ | ±20%rdg±5dgt | 1GΩ | ||
5TΩ~35TΩ | ±35%rdg±10dgt | 0.01TΩ | ||
15kV(±10%) | 0 MΩ~60MΩ | ±5%rdg±5dgt | 0.01MΩ | |
60 MΩ~600MΩ | ±5%rdg±5dgt | 0.1MΩ | ||
600 MΩ~6000MΩ | ±5%rdg±5dgt | 1MΩ | ||
6 GΩ~60GΩ | ±5%rdg±5dgt | 0.01GΩ | ||
60 GΩ~600GΩ | ±10%rdg±5dgt | 0.1GΩ | ||
600 GΩ~6000GΩ | ±20%rdg±5dgt | 1GΩ | ||
6 TΩ~50TΩ | ±35%rdg±10dgt | 0.01TΩ |
Capacitance Measuring Range & Accuracy
Measuring function | Measuring range | accuracy | resolution |
Capacitance | 10uf-50uf | ±15%rdg±5dgt | 0.01uf |
1uf-10uf | ±15%rdg±5dgt | 0.1uf | |
100nf-10nf | ±15%rdg±5dgt | 0.01nf | |
10nf-100nf | ±15%rdg±5dgt | 0.01nf |
15kV DC Insulation Resistance Tester HIT-15 is powerful tool for measuring insulation resistance of cables, transformers, motors / generators, circuit breakers and bushings etc.