Portable PQ Analyzer
Model: PQA-400
Current electric power applications, due to more and more large power equipment, the complex power grid system and the fault is becoming more and more complex, more and more difficult to troubleshoot, and due to the development of the industry of power grid power quality request more and more is also high. For this purpose, we provide this kind of measuring and analyzing instrument PQA-400 which can eliminate complex power system faults more quickly and accurately, and monitor and maintain power quality parameters more comprehensively and systematically.
The Portable PQ Analyzer PQA-400 is a highly intuitive and advanced portable 3-phase analyzer. IP54 weatherproof enclosure is designed for outdoor operation. The
unit is robust enough to remain recording outdoors.
The Portable PQ Analyzer PQA-400 can simultaneously measure the 4-channel current(ABC three phase and neutral wire cur-rent), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic etc.; display real-time waveform, harmonic ratio bar charts of current voltage; dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
The PQA-400 can record for extended periods of time because of its massive memory. It utilizes a built-in 2G memory card which makes expanding the memory easy. The recorded data can be viewed on the LCD display of PQA-400. The data also can be transferred to the PQ analysis software via USB cable.
Technical Data
Power supply | Rechargeable lithium-ion battery packs 9.6V, backup charger. |
Battery indicator | Battery symbol 5 cells display the power. When the battery power is too low, it prompts automatic shutdown after 1 minute. |
Power consumption | Current consumption of normal test 490 mA, continuous working for 10 hours. |
Display mode | LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. |
Size of clamp |
HR-008 small sharp current clamp: 7.5mm×13mm HR-020 circle current clamp: 20mm×20mm HR-050 circle current clamp: 50mm×50mm |
Instrument dimensions | L×W×H: 277mm×227.5mm×153 mm |
Number of channels | 4U & 4I |
Phase-to phase voltage | 1.0V~2000V |
Phase-to-neutral voltage | 1.0V~1000V |
Current |
HR-008 current clamp: 10mA~10.0A; HR-020 current clamp: 0.10A~100A; HR-050 current clamp: 1.0A~1000A; HR-300R Rogowski Coil with Integrator: 10A ~ 6000A |
Frequency | 40Hz~70Hz |
Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ |
Energy parameters | Wh, Varh, Vah |
Harmonic | Order 0~50. |
Total harmonic distortion | Order 0~50, each phase |
Expert mode | Yes |
Number of Transient records | 150 sets |
Voltage flicker | Yes |
Starting current mode | Yes, 100 seconds |
3 phases unbalance | Yes |
Record | 300 days(simultaneous recording 20 parameters, record one point every 5 seconds). |
Min/Max recorded value | Measurement of maximum and minimum values over a period of time. |
Alarm | 40 different types of parameter selections, 12,800 sets alarm logs. |
Peak | Yes |
Phasor diagram display | Automatically |
Capacity of snapshots | 60 |
Menu language | English/Chinese |
Communication | USB |
Automatic switching off | When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off. |
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute. | |
Backlight function | Yes, suitable for use at night and dark place. |
Weight | Host: 2.41kg (with battery). |
HR-008 small sharp current clamp: 168g×4 | |
HR-020 circle current clamp: 252g×4 | |
HR-050 circle current clamp: 463g×4 | |
HR-300R Rogowski Coil with Integrator: 280g×4 | |
Test wires and power adapter: 800g | |
Total weight: about 10.8kg (with packaging) | |
Length of voltage test wire | 3m |
Length of current sensor wire | 2m |
Working temperature and humidity | -10°C~40°C; below 80%Rh. |
Storage temperature and humidity | -10°C~60°C; below 70%Rh. |
Input impedance | Input impedance of test voltage: 1MΩ. |
Withstand voltage | Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. |
Insulation | Between instrument wiring and shell ≥10MΩ. |
Structure | Double insulation, with insulation vibration-proof sheath. |
Safely rules | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
The Portable PQ Analyzer PQA-400 is the ideal tool for testing power quality in any environment. It makes the testing more efficient, and enables the operator to quickly and easily analyze test results.