Ultraportable Six-phase Relay Test System
Model: RELAYSTAR-S60
The RELAYSTAR-S60 is ultra-portable protection relay test system that delivers performance verification testing of electromechanical, solid-state and microprocessor-based protective relays in their operating installations.
The RELAYSTAR-S60 is a rugged test set suitable for testing a variety of protective relays operated in both indoor and outdoor environments. The unit’s ergonomic design and intuitive control panel layout make it ideal for first-time users who have little or no training.
Main Features:
1) 6-phase current(6×30A) + 6-phase voltage(6×150V) output
2) Embedded industrial PC with 10.4-inch LCD screen
3) Convenient front-panel display indicates active voltage/current amplitudes and phase values during testing
4) Analog testing of 1A and 5A protection devices
5) Perform state simulation and transient testing
6) COMTRADE viewer and playback
7) Lower weight: only 10.6kg(26.37 lb)
Technical Data
Current Generator
Setting range | 6-phase AC(L-N) | 6x0…30A |
3-phase AC(L-N) | 3x0…60A | |
1-phase AC(LL-LN) | 1x0…180A | |
DC(L-N) | 6x0…±10 A | |
Power | 6-phase AC(L-N) | 6x200VA at 30A |
3-phase AC(L-N) | 3x300VA at 60A | |
1-phase AC(LL-LN) | 1x600VA at 180A | |
DC(L-N) | 6x100VA at 10A | |
Accuracy | AC: ±1mA(≤0.2A), ≤0.1% (0.2~30A) | |
DC: ±5mA(0.2~0.5A), ≤0.2% (0.5~10A) | ||
Resolution | 1mA |
Voltage Generator
Setting range | 6-phase AC(L-N) | 6x0…150V |
3-phase AC(L-N) | 3x0…300V | |
DC(L-N) | 6x0…±160V | |
Power | 6-phase AC(L-N) | 6x60VA at 150V |
3-phase AC(L-N) | 3x100VA at 300V | |
DC(L-N) | 6x60VA at 160V | |
Accuracy | AC: ±2mV(0.2~2V), ≤0.1% (2~150V) | |
DC: ±10mV (0.5~5V), ≤0.2% (5~160V) | ||
Resolution | 1mV |
Binary Inputs
Number | 8 |
Input characteristics | idle contact or potential-free contact |
Threshold characteristics | “0”:0~6V; “1”:12V~250V |
Max. measuring time | 999999.999s |
Time accuracy | ±1ms |
Time resolution | 1ms |
Binary Outputs
Number | 4 |
Type | idle contact |
Break capacity | 250VAC/0.5A, 250VDC/0.2A |
General Generators
Frequency | range: 0~1200Hz |
accuracy:<1mHz(0~65Hz);<10mHz(65~450Hz);<20mHz(450~1200Hz) | |
resolution: 0.001Hz | |
Phase | range: -360° ~+360° |
accuracy: 0.1° | |
resolution: 0.01° | |
Harmonic | superposition order: 2~24 times |
distortion: ≤0.5% |
Power Supply
Nominal input voltage | customized (AC 220V/230V/120V±10%, 1-phase) |
Nominal frequency | 50/60 Hz |
Rated current | 10A at 230V / 12A at 115V |
Connection | standard AC socket (IEC 60320) |
Environmental Conditions
Operation temperature | 0 ... +50 °C (+32 ... +122 °F) |
Storage temperature | -25 ... +70 °C (-13 ... +158 °F) |
Humidity range | relative humidity 5 ... 95 %, non-condensing |
Vibration | IEC 60068-2-6(20m/s2 at 10 ... 150 Hz) |
Miscellaneous
Weight | 10.6kg(26.37 lb) |
Dimensions (W x H x D, without handle) | 350×250×120mm(13.78x9.84x4.72 in) |
Connection port | 2 USB2.0 ports, 1 Ethernet port |
Safety Standards, Electromagnetic Compatibility
EMC | The product adheres to the electromagnetic compatibility (EMC) Directive 2004/108/EC(CE conform) |
IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3 | |
Safety | The product adheres to the low voltage Directive 2006/95/EC(CE conform). |
IEC 61010-1 |
Ultraportable Six-phase Relay Test System RELAYSTAR-S60 is an excellent choice for testing and commissioning engineers to perform protection relay testing on site.
Ultraportable Six-phase Relay Test System RELAYSTAR-S60 is quite convenient to carry for users due to super-small size and much lower weight 10.6kg(26.37 lb).
Ultraportable Six-phase Relay Test System RELAYSTAR-S60 is capable to test all generations and types of protection relays as below according to requirements of ANSI/IEEE.
ANSI / IEEE No. | Device or Function Name |
2 | Time Delay Staring |
3 | Checking or Interlocking Relay |
7 | Rate-of-change Relay |
13 | Synchronous-speed Device |
15 | Speed or Frequency, Matching Device |
16 | Data Communication Device |
18 | Accelerating or Decelerating Device |
21 | Distance Relay |
24 | Volts per Hertz Relay |
25 | Synchronizing or Synchronism-check Device |
27 | Undervoltage Relay |
30 | Annunciator Relay |
32 | Directional Power Relay |
36 | Polarity or Polarizing Voltage Device |
37 | Undercurrent or Underpower Relay |
40 | Field Relay |
44 | Unit Sequence Starting Relay |
46 | Reverse-phase or Phase-balance Current Relay |
47 | Phase-sequence Voltage Relay |
48 | Incomplete Sequence Relay |
50 | Instantaneous Overcurrent or Rate of Rise Relay |
51 | AC Time Overcurrent Relay |
55 | Power Factor Relay |
59 | Overvoltage Relay |
60 | Voltage or Current Balance Relay |
62 | Time-delay Stopping or Opening Relay |
66 | Notching or Jogging Device |
67 | AC Directional Overcurrent Relay |
68 | Out-of-step or Blocking Relay |
69 | Permissive Control Device |
74 | Alarm Relay |
76 | DC Current Relay |
77 | Telemetering Device |
78 | Phase-angle Measuring Relay |
79 | AC Reclosing Relay |
81 | Frequency Relay |
82 | DC Load-measuring Reclosing Relay |
83 | Automatic Selective Control or Transfer Relay |
85 | Carrier or Pilot-wire Receiver Relay |
86 | Lockout Relay |
87 | Differential Protective Relay |
91 | Voltage Directional Relay |
92 | Voltage and Power Directional Relay |
94 | Tripping or Trip-free Relay |
-- | Phasor Measurement Unit |
-- | Power Quality Monitor |