Specifications
Brand Name :
HAOMAI
Model Number :
CTP-120PA
Certification :
ISO9001:2015, Calibration Report
Place of Origin :
China
MOQ :
1 set
Price :
negotiation
Payment Terms :
T/T
Supply Ability :
400 sets per month
Delivery Time :
5-10 working days
Packaging Details :
Transport Case + Plywood Case
Product name :
CT Analyser, CT Tester, CT Test Set
Multi-ratio CT testing :
Available
Current output :
0-12A(RMS), 36A(peak value)
Voltage output :
0-180V(RMS)
Measuring Accuracy of CT Ratio :
±0.05%
Operation :
local mode + PC mode
Description

High Precision Current Transformer Analyzer

Model: CTP-120PA

The portable and high precision current transformer analyzer CTP-120PA allows performing all tests foreseen by international standards on CTs and inductive VTs.

For CT tests, the instrument can be connected directly up to 6 taps via Multi-tap Switch Box. In this way the connection to the device under test it’s executed only one time without the need of any further manual operation.

The CTP-120PA can be used as a stand-alone unit or can be computer-controlled. It can be connected to a PC via the USB port. In computer-controlled mode, test records can be read from the CTP-120PA’s memory, or CT tests can be run from the PC. The CTP-120PA comes with the CTP PC software. The CTP PC software can be used to test a current transformer or voltage transformer directly from a PC, automatically generate test results, read test records from the CTP-120PA’s memory, and save test records in Word format.

The instrument is housed in a transportable box, which is provided with a cover and handles for ease of transportation.

Main Features

●Able to test Protection CTs, Measuring CTs, TP class CTs and inductive PTs

●Test excitation characteristic and error curve based on low-frequency measurement principle

●Measure ratio, polarity, ratio error and phase displacement error based on voltage method

●Capable of testing multi-ratio CTs automatically without the need for rewiring

●Adopt patented multifunctional rotary mouse to replace the keypad

●Adopt 5.7 inches LCD screen for display

●Adopt DSP, ARM and embedded LINUX operation system

●Both local test and PC remote test available

●Higher measurement accuracy: 0.05%

●Print test results directly by built-in thermal printer

●Small and light weight (9kg / 19.84 lbs) for easy transport

Technical Data

●Test Standard: IEC61869-2(IEC60044-1,60044-6), IEC61869-3(IEC60044-2), IEEE/ANSI C57.13

●Maximum Knee Voltage Measurement: 40kV

●Output Range:

voltage: 0~180V(RMS)

current: 0~12A(RMS), 36A(peak value)

●Voltage Measurement Accuracy: ±0.05%

●CT Ratio Measurement:

range:1~30000

accuracy: ±0.05%

●PT Ratio Measurement:

range:1~10000

accuracy: ±0.05%

●Phase Measurement:

accuracy: ±2min

resolution: 0.01min

●Secondary Winding Resistance Measurement:

range: 0~300Ω

accuracy: 0.1%±1mΩ

●Burden Measurement:

range: 0~300VA

accuracy: 0.1%±0.1VA

●Memory Capacity: >3000 groups test results

●Power Supply

Nominal input voltage customized (AC220V/230V/120V±10%, 1-phase)
Nominal frequency 50/60 Hz
Rated current 10A at 230V / 12A at 120V
Connection standard AC socket (IEC 60320)

●Environmental Conditions

Operation temperature 0 ... +50 °C (+32 ... +122 °F)
Storage temperature -25 ... +70 °C (-13 ... +158 °F)
Humidity range relative humidity 5 ... 95 %, non-condensing
Vibration IEC 60068-2-6(20m/s2 at 10 ... 150 Hz)

●Miscellaneous

Weight 9kg(19.84 lbs)
Dimensions (W x H x D, without handle) 340×300×150mm(13.39x11.81x5.91 in)
Connection port 2 USB2.0 ports, 1 communication port

The portable and high precision current transformer analyzer CTP-120PA is a powerful tool for performing all tests of CTs and inductive VTs.

Send your message to this supplier
Send Now

9kg Multitap CT PT Current Transformer Analyzer IEC Test Standard

Ask Latest Price
Brand Name :
HAOMAI
Model Number :
CTP-120PA
Certification :
ISO9001:2015, Calibration Report
Place of Origin :
China
MOQ :
1 set
Price :
negotiation
Contact Supplier
9kg Multitap CT PT Current Transformer Analyzer IEC Test Standard
9kg Multitap CT PT Current Transformer Analyzer IEC Test Standard

HAOMAI ELECTRIC TEST EQUIPMENT CO.,LTD

Active Member
4 Years
shenzhen
Since 1999
Business Type :
Manufacturer
Total Annual :
16500000-18000000
Employee Number :
230~270
Certification Level :
Active Member
Contact Supplier
Submit Requirement