High Voltage 6-phase Relay Test System
Model: RELAYSTAR-H60
The RELAYSTAR-H60 is portable 6-phase relay test system for testing most types of modern multi-function protection relays, which can output 6-phase current(6x0…32A) and 4-phase voltage (4x0…300V).
The RELAYSTAR-H60 is an excellent choice when you want higher output voltage(4-phase AC voltage: 4x0…300V, 4-phase DC voltage: 4x0…±300V).
High Voltage 6-phase Relay Test System RELAYSTAR-H60 can be also used as a fault simulator to ensure proper relay configuration for specific applications. This is possible by importing and re-generating transient disturbance files often referred to as COMTRADE files.
Main Features
1) 6-phase current(6×32A) + 4-phase voltage(4×300V) output
2) Higher output accuracy(≤0.05% for AC output)
3) End to end test via in-built GPS
4) In-built waveform monitoring and recording
5) Abundant binary inputs and binary outputs
5) Independent Aux. DC supply
6) Powerful RELAYSTAR test software
Technical Data
Current Generator
Setting range | 6-phase AC(L-N) | 6x0…32A |
3-phase AC(L-N) | 3x0…64A | |
1-phase AC(LL-LN) | 1x0…192A | |
DC(L-N) | 6x0…±15A | |
Power | 6-phase AC(L-N) | 6x240VA at 32A |
3-phase AC(L-N) | 3x400VA at 64A | |
1-phase AC(LL-LN) | 1x750VA at 192A | |
DC(L-N) | 6x240VA at 15A | |
Accuracy | AC: ±2.5mA(≤0.5A), ≤0.05% (0.5~32A) | |
DC: ≤0.1% | ||
Resolution | 1mA |
Voltage Generator
Setting range | 4-phase AC(L-N) | 4x0…300V |
1-phase AC(L-L) | 1x0…600V | |
DC(L-N) | 4x0…±300V | |
Power | 4-phase AC(L-N) | 4x80VA at 300V |
1-phase AC(L-L) | 1x160VA at 600V | |
DC(L-N) | 4x80VA at 300V | |
Accuracy | AC: ±5mV(≤5V), ≤0.05% (5~300V) | |
DC: ≤0.1% | ||
Resolution | 1mV |
Auxiliary DC Supply
Voltage range | 0-300V |
Output accuracy | ≤0.5% |
Power | max.160VA |
Binary Inputs
Number | 10 |
Input characteristics | idle contact or potential-free contact |
Threshold characteristics | “0”:0-6V; “1”:11V-250V |
Max. measuring time | 999999.999s |
Time accuracy | ≤0.1ms |
Time resolution | 0.1ms |
Binary Outputs
Number | 8 |
Type | idle contact |
Break capacity | 250VAC/0.5A, 250VDC/0.2A |
DC Voltage Measuring Input
Measuring range | 0 ... ±10 V |
Accuracy | error < 0.02 % rg. typ., < 0.05 % rg. guar. |
DC Current Measuring Input
Measuring range | 0 ... ±20 mA |
Accuracy | error < 0.02 % rg. typ., < 0.05 % rg. guar. |
In-built Monitoring and Recording
Monitoring | 6-phase current and 4-phase voltage outputs |
Recording | analog outputs |
Mode | real time monitoring, no external wiring is required |
Recording length | unlimited (until the internal memory is full) |
General Generators
Frequency | range: 0~1200Hz |
accuracy:<1mHz(0~65Hz),<2mHz(65~450Hz),<5mHz(450~1200Hz) | |
resolution: 0.001Hz | |
Phase | range: -360° ~+360° |
accuracy: 0.1° | |
resolution: 0. 1° | |
Harmonic | superposition order: 2~24 times |
distortion: ≤0.5% |
Power Supply
Nominal input voltage | AC220V/230V±10%, 1-phase |
Nominal frequency | 50/60 Hz |
Rated current | 10A at 230V |
Connection | standard AC socket (IEC 60320) |
Miscellaneous
Weight | 14.8kg(32.63 lb) |
Dimensions (W x H x D, without handle) | 392x272x237mm(15.43x10.71x9.33 in) |
Connection port | 1 Ethernet port |
Environmental Conditions
Operation temperature | 0 ... +50 °C (+32 ... +122 °F) |
Storage temperature | -25 ... +70 °C (-13 ... +158 °F) |
Humidity range | relative humidity 5 ... 95 %, non-condensing |
Vibration | IEC 60068-2-6(20m/s2 at 10 ... 150 Hz) |
High Voltage 6-phase Relay Test System RELAYSTAR-H60 is the portable and reliable tool for engineers to perform protection relay testing in substation.
High Voltage 6-phase Relay Test System RELAYSTAR-H60 can test all types of protection relays virtually according to requirements of ANSI/IEEE.