RS485 output water tank controller static Submersible level transmitter level sensor
Description of RS485 output water tank controller static Submersible level transmitter level sensor
Submersible liquid level transmitter series static pressure submersible liquid level transmitter (liquid level gauge) is suitable for liquid level measurement of various media in petrochemical, metallurgy, electric power, pharmaceutical, water supply and drainage, environmental protection and other systems and industries. Exquisite structure, simple adjustment and flexible installation provide convenience for users to use easily. 4~20mA, 0~5v, 0~10mA and other standard signal output methods can be selected by users according to their needs.
Dimension of RS485 output water tank controller static Submersible level transmitter level sensor
Specification of RS485 output water tank controller static Submersible level transmitter level sensor
Pressure Span | 0...200mH2O |
Output Signal | 4...20mA,0-5V,0.5-4.5V |
Supply Input | 10…36V DC;5V |
Accuracy | +/-0.5%FS |
Non-Linearity | +/-0.250% FS |
Repeatability | +/-0.10% FS |
Thermal Error | +/-0.2% FS/oC |
Zero Drift | +/-0.25% FS |
Long Term Stability | +/-0.5% FS/Year |
Over Pressure Safety | 200% |
Operating Temperature | 0oC to 50oC |
Response Time | <1ms (10-90%FS) |
Diaphragm | titanium alloy Stainless Steel |
Case Material | 1Cr18Ni9Ti Stainless Steel |
Compatibility | Liquid compatible with titanium alloy |
Protection | IP68 |
Feature of RS485 output water tank controller static Submersible level transmitter level sensor
1. Good stability, the long-term stability of full scale and zero position can reach 0.1%FS/year. The temperature drift is less than 0.1%FS within the compensation temperature range of 0 to 70°C, and less than 0.3%FS within the entire allowable operating temperature range.
2. It has reverse protection and current-limiting protection circuit. When the positive and negative poles are reversed during installation, the transmitter will not be damaged. When abnormal, the transmitter will automatically limit the current within 35MA.
3. Solid-state structure, no moving parts, high reliability and long service life.
4. easy installation, simple structure, economical and durable.
Application of RS485 output water tank controller static Submersible level transmitter level sensor
Submersible level gauges are widely used in water level monitoring fields such as urban water supply and drainage, sewage treatment, groundwater, reservoirs, rivers, and oceans.
Detaild picture of RS485 output water tank controller static Submersible level transmitter level sensor
![]() | ![]() |
![]() | ![]() |