This series of input type liquid level transmitters are based on the principle that the measured liquid static pressure is proportional to the height of the liquid. The product uses the piezoresistive effect of ceramic sensitive elements to convert the static pressure into an electrical signal, and then cooperates with a dedicated digital circuit to pass the signal Amplification, linear compensation, anti-interference, anti-surge protection and other signal processing, an integrated product that outputs industry standard signals.
Load (Ω)
Current (2-wire system): ≤ (power supply voltage-8V) /0.02A
Voltage (3-wire system):> Maximum output signal / 1mA
Proportional voltage (3-wire system):> 10K
Supply voltage
Total current consumption
Current (2-wire system): signal current, maximum 25mA
Voltage (3-wire system): 2.5mA
Proportional voltage (3-wire system): 2.5mA
Long-term stability
Anti-vibration
10g (IEC 60068-2-6 standard, under resonance conditions)
Impact resistance
500g (IEC 60068-2-27 standard, mechanical shock)
Service life
1 million pressure cycles
YD322-A level transmitter | ||
Measure range | ||
Cable Length | A | 5m(default) |
B | 10m | |
C | customer request | |
Output | 1 | 2 wire(4~20)mA(default) |
2 | (0~5)VDC | |
3 | (0~10)mA | |
4 | customer request | |
Accuracy | 1 | 0.1% |
2 | 0.25% | |
3 | 0.5%(default) | |
Display | 1 | No display(default) |
2 | 2088LCD | |
3 | 2088LED |