Description Stainless steel pressure gauge manometer movement
YTFN stainless steel pressure gaugemanufactured by Xian Yunyi Instrument.It consists of a pressure guiding system (including joints, spring tubes, current limiting screws, etc.), a gear transmission structure, a display device (pointer and dial), and an outer casing (including a case, a cover, a window, etc.). The outer casing is airtight and can effectively protect the internal parts from the environment and dirt.
Detailed Images Stainless steel pressure gauge manometer movement
Specification Stainless steel pressure gauge manometer movement
1 Thread specification: M20 * 1.5
2 Characteristics: corrosion resistance to high temperature
3 Material: all the 316 stainless steel material
4 Medium temperature: 200 ° C or less
5 Use working temperature: -40 °C ~ 70 °C
6 Working pressure limit: not more than the upper limit of 2/3
Technical indicators Stainless steel pressure gauge manometer movement
1.Accuracy class: 1.6, 2.5,1.0(custom)
2.Measuring range: (Mpa) (custom)
0-0.16 0-0.25 0-0.1 0-0.4
0-0.6 0-1.6 0-2.5 0-1
0-40-60-100-16
0-250-400-60
-0.1-0 -0.1-0.06 -0.1-0.15 -0.1-0.3
-0.1-0.5 -0.1-0.9 -0.1-1.5 -0.1-2.4
3.Parts material: SUS316, SUS316L, 1Crl8Ni9Ti(custom)
4.Case Material :Stainless Steel SUS 304
5. The instrument nominal diameter: Φ60mm Φ100mm Φ150mm Φ200mm( custom)
6. Connector thread size: M20X1.5 (G3 / 8 ", Gl / 4", NPTl / 2 "or custom)
7.Working conditions:
(1) Ambient temperature: -40-70 ℃
(2) Working pressure: Static load: with a scale value 3/4 alternating load: The scale value short 2/3 pressure: the scale value
8.Type Dry (Liquid Fillable)
9.Mount Lower/back
Selection Guide Stainless steel pressure gauge manometer movement
Dial Size | 60mm,100mm,150mm, 200mm | |||
Pressure range | -0.1~0Mpa~60~250Mpa | |||
Case Material: | 304 stainless steel, 316 stainless steel. | |||
Connector thread: | M14 × 1.5; G1 / 4; M20 × 1.5; 1/2 NPT and so on. | |||
Connection threads | NPT, BSP (G, PF), BSPT (ZG, PT) | |||
Case form: | containment structure, release after partition device | |||
Connector | stainless steel, Brass | |||
Pointer: | Normal | |||
Dial plate | single and dual scale (psi, kpa,mpa, bar, kg/cm2 avaible) | |||
Table glass: | plexiglass, safety double glazing | |||
Seismic filling material | glycerin 98% (optional silicone oil, fluorine oil or other categories) | |||
Accuracy range | 1%, 1.6%, 2.5% | |||
Working temperture | -40°C- 70°C(no liquid in the shell) -25 ~ 70 ℃ (filled in the shell) |