tuf-2000h+tm1+tl-1 portable handheld ultrasonic flowmeter
Description tuf-2000h+tm1+tl-1 portable handheld ultrasonic flowmeter
This flowmeter can be virtually applied to a wide range of measurement. A variety of liquid applications can be accommodated: ultra-pure liquids, potable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent. etc
Features tuf-2000h+tm1+tl-1 portable handheld ultrasonic flowmeter
High-precision measurement, measurement accuracy is better than ±1%, linearity is 0.5%, repeatability accuracy is 0.2%, small size and light weight, volume: 210 × 90 × 3OMM, weight is only 0.5KG
● Non-contact measurement, the magnetic ultrasonic flowmeter sensor is adsorbed on the outer wall of the pipeline to complete the flow measurement
●Large measurement range, different types of sensors can be used to measure the flow of pipes with a diameter of DN20~DN6000
●Rechargeable power supply, built-in high-capacity NiMH rechargeable battery, can support the flowmeter to work continuously for more than 12 hours
●Large-screen LCD display can simultaneously display cumulative flow, instantaneous flow, flow rate, working status, etc.
●Built-in data logger, built-in data logger, the space is 24K bytes, and it can store 2000 lines of measurement data.
Parameter tuf-2000h+tm1+tl-1 portable handheld ultrasonic flowmeter
Items Performance & Parameter | ||
Convertor | Principle | Transit- time ultrasonic flowmeter |
Accuracy | ±1% | |
Display |
4×16 character LCD with backlight, support the language of Chinese, English and Italy | |
Data Interface |
Insulate Rs232 serial interface, upgrade the flowmeter software by computer | |
Pipe Installation Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed |
Pipe Diameter | 25~6000mm | |
Straight Pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump | |
Measuring Medium |
Type of Liquid | Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil ( crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals ( alcohol, etc.); Plant effluent; Beverage; Ultra- pure liquids, etc. |
Temperature | - 30~160℃ | |
Flowrate | 0~±10m/ s | |
Working Environment | Temperature | Convertor:- 20~60℃;Flow Transducer:- 30~160℃ |
Humidity | Convertor: 85% RH;Flow Transducer: Ip67 | |
Power Supply |
3 AAA built-in Ni-MH batteries 1.2V(for over 12 hours of operation). 90V-260V AC adapter | |
Power Consumption | 1. 5W | |
Case Material | ABS | |
Dimension | 200*93*32MM(Convertor) |
Types | Spec. | Model | Measurement Range | Temperature | Dimension |
Clamp on | Small Size | TS- 2 | DN15~ DN100 | - 30~ 90℃ | 45×25×32mm |
Medium Size | TM- 1 | DN50~ DN700 | - 30~ 90℃ | 64×39×44mm | |
Large Size | TL- 1 | DN300~ DN6000 | - 30~ 90℃ | 97×54×53mm | |
High Temperature Clamp on | Small Size | TS- 2- HT | DN15~ DN100 | - 30~ 160℃ | 45×25×32mm |
Medium Size | TM- 1- HT | DN50~ DN700 | - 30~ 160℃ | 64×39×44mm | |
Large Size | TL- 1- HT | DN300~ DN6000 | - 30~ 160℃ | 97×54×53mm | |
Mounting Bracket Clamp on | Small Size | HS | DN15~ DN100 | - 30~ 90℃ | 318×59×85mm |
Medium Size | HM | DN50~ DN300 | - 30~ 90℃ | 568×59×85mm | |
Extended | EB- 1 | DN300~ DN700 | - 30~ 90℃ | 188×59×49mm | |
High Temperature Mounting Bracket Clamp on | Small Size | HS- HT | DN15~ DN100 | - 30~ 160℃ | 318×59×110mm |
Medium Size | HM- HT | DN50~ DN300 | - 30~ 160℃ | 568×59×110mm | |
Extended | EB- 1- HT | DN300~ DN700 | - 30~ 160℃ | 188×59×49mm |