LDC11Y Pipeline Electromagnetic Flowmeter is a velocity flow meter, which is the product of the combination of fluid mechanics and electromagnetics. It consists of two parts: a flow sensor and a converter. The upper and lower parts of the measuring tube are equipped with an excitation coil, and the magnetic field generated after passing through the excitation current passes through the measuring tube, and a pair of signal electrodes are installed on the inner wall of the measuring tube to contact with the liquid, generating an induced electric potential, and the flow signal is transmitted to the converter, which is converted into a standard signal for output after the converter. It has the advantages of high precision, high stability, anti-interference, and maintenance-free.
Basic parameters | |
Measuring medium | Liquid (the conductivity of the measured fluid should be > 20μS/cm and compatible with the contact material) |
Flow rate range | 0.1m/s-15m/s |
Measuring range | 0.05~21700m3/h |
Range ratio | 10:1 (15:1, 20:1, 30:1 can be customized) |
Flow direction | Positive, negative, net flow |
Repeatability error | 1/3 of the absolute value of accuracy level |
Accuracy level | 0.5 level, 0.2 level |
Medium temperature | -20℃~60℃ (Chloroprene CR lining) -20℃~60℃ (Polyurethane rubber PU lining) -30℃~120℃ (PTFE lining) -30℃~150℃ (High temperature PTFE lining) -30℃~100℃ (Fluorinated ethylene propylene F46 lining) -20℃~150℃ (PTFE and perfluoroalkyl vinyl copolymer PFA lining) |
Output signal | 4~20mA, frequency/pulse, alarm output, RS485, HART |
Power supply | 85~250VAC,20~36VDC |
Explosion-proof type | Ex db ib q IIC T6 Gb (compound explosion-proof including isolation type, intrinsic safety type, sand filling type) |
Connection | Flange connection DN6-DN2000 (implementation standard GB/T9124.1-2019) |
Protection level | Integrated IP66 Split sensor IP66/IP68 Display box IP66 Note 1/When the split sensor is IP68, the burial depth is less than 5m and the water penetration depth is less than 3m. Note 2/The above protection level refers to the level achieved after the electrical connection is complete. |
Maximum Power | ≤20W |
Show Header | LCD (with backlight) |
Instrument function | |
monitor | Volume flow, mass flow, instantaneous flow, cumulative flow, flow velocity |
Call the police | Empty pipe identification alarm, electrode contamination alarm, excitation alarm |
Current output | |
Maximum load | 750Ω(24V power supply) |
Response frequency | 1Hz |
Frequency Output | |
Frequency output range | 1~5000Hz |
Output electrical isolation | Optical isolation, isolation voltage>1000VDC |
Frequency output driver | Field effect tube output, maximum withstand voltage 36VDC, maximum load current 250mA |
Pulse output | |
Pulse equivalent | 0.001~1.000 m3/cp n0.001~1.000 Ltr/cp n0.001~1.000 T/cp |
High level amplitude | >22VDC |
Low level amplitude | <0.8VDC |
Pulse Width | 50ms (square wave), automatic average square wave at high frequency |
Electrical isolation | Optical isolation, isolation voltage>1000VDC |
Pulse drive | Field effect tube output, maximum withstand voltage 36VDC, maximum load current 250mA |
Alarm output | |
Alarm output contact | ALMH-Upper limit alarm ALML-Lower limit alarm |
Output electrical isolation | Optical isolation, isolation voltage>1000VDC |
Alarm output driver | Darlington output, maximum withstand voltage 36VDC, maximum load current 250mA |
RS485 output | This protocol complies with the Modbus communication protocol and adopts the RTU mode in the Modbus protocol. RS485 half-duplex working mode (see the protocol description for details). |
Environmental conditions | |
Ambient temperature | -20~60℃ |
Ambient humidity | 0%~95%RH (no condensation and no condensation) |
Electrical protection | |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength | 500VAC |
Overall material | |
Lining material | Neoprene CR, polyurethane rubber PU, polytetrafluoroethylene PTFE, high temperature polytetrafluoroethylene PTFE, polyperfluoroethylene propylene F46, copolymer of polytetrafluoroethylene and perfluoroalkyl vinyl PFA (contacting the measured medium) |
Electrode material | Titanium, Hastelloy C, Tantalum, Tungsten Carbide, Platinum, 316L (in contact with the measured medium) |
Sensor housing | Carbon steel/304 stainless steel |
Flange material | Carbon steel/304 stainless steel |
Converter housing | Die-cast aluminum |
Converter seals | Nitrile rubber |
Display window | ≈6mm explosion-proof glass |
Connect the cables | Cable between sensor and converter 2*0.5 OD 6.5mm PVC shielded cable (split type) |