CYW12CY Protective Submersible Level Transmitter Range 0~1~200mH2O Output 4~20mA HART RS485 Accuracy 0.25%FS 0.5%FS
This level transmitter product adopts stainless steel double isolation diaphragm OEM pressure sensor as the signal measurement element, the internal sealing treatment, the external use of the integral laser welding process, so that it has the function of anti-condensation in the cavity, and after automatic computer testing, the laser resistance process is used for a wide temperature range of zero point and sensitivity temperature
Compensate. It is anti-interference, small temperature drift, high stability, and has high measurement accuracy, which is an ideal liquid level measuring instrument in the field of industrial automation.
Base parameters | |
Measuring medium | Water (H2O) or liquids compatible with contact materials |
Measuring range | 0~1~200mH2O (see range selection table for details) |
Media temperature | -40~85℃ |
Response frequency | Analog signal output≤ 50Hz, digital signal output ≤5Hz |
Stable performance | ± 0.1% FS/year |
Overload capacity | 200% full scale |
Temperature compensation | -10~70℃ |
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
Accuracy class | 0.25%FS (range≥10m), 0.5%FS (range<10m) with repeatability≤0.05%FS, hysteresis≤0.05%FS Header accuracy 0.5%FS<b15> Liquid crystal (LCD) display Note: Reference conditions: temperature 25~86°C, atmospheric pressure 106~45kPa, humidity 75~<>%RH. |
Ex type | Flameproof Ex db II.C T6 Gb Flameproof Dust Type Ex tb IIIC T80°C Db
Intrinsically Safe Ex ia II.C T6 Ga (4~20mA/4~20mA HART output only) |
Degree of protection | Probe IP68 Junction Box IP66 Note: The above protection level refers to the electrical connection is complete |
Overall weight | No display≈ 1.25kg with display≈1.4kg probe≈ 410g cable ≈ 60g per meter |
On-time | 400ms |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Output power | |
Maximum power | |
4~20mA | Yes/No Display≤0.02Us(W) |
RS485 | With display≤0.02Us(W), No display≤0.015Us(W) |
4~20mA HART | Yes/No Display≤0.02Us(W) |
Load characteristics | |
Current type | No display load ≤{(US-7.5)÷0.02}Ω with display load ≤{(US-12)÷0.02}Ω (Us=supply voltage) HART current type: load ≤{(Us-12)÷0.02}Ω (Us=supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85°C(no condensation, no condensation) |
Overall material | |
Diaphragm | 316L stainless steel (contact with the medium to be measured) |
Outer shell | 304 stainless steel (contact with the medium to be measured) |
Junction box | Die-cast aluminum |
Seals | Nitrile rubber (contact with the medium to be measured) |
Cable | Polyurethane φ7.2 gas cable (contact with the measured medium) |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard |
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ,500VDC |
Dielectric strength | 500VAC |
Output limits | |
4-20mA | Output min. 2.5mA, output max 26mA |
RS485 | Output minimum 0 and output maximum 2000 |
4-20mA HART | Output min. 3.8mA, output max 22mA |