CYYZ36RY Fused Type Pressure Transmitter High temperature adhesive melting equipment Range 0-1MPa~60MPa
The CYYZ36RY melt type pressure transmitter is meticulously designed, compact in structure, resistant to vibration, frequent high pressure impact, and wear-resistant, suitable for medium with easy solidification of melt within 200 ℃.
Basic parameters | |
Measuring medium | Glue, slurry, crude oil, etc. (compatible with contact materials) |
Measuring range | 0~1MPa~60MPa (see range selection table for details) |
Type of pressure | Gauge pressure |
Output signal | 4~20mA,RS485 |
Supply voltage | 9~36VDC |
Accuracy class | 0.5%FS |
Medium temperature | -40~200℃ |
Turn-on time | 20ms |
Stable performance | ±0.1% FS/year |
Temperature compensation | -10~70℃ |
Temperature drift | ±0.01%FS/°C (within temperature compensation) ±0.05%FS/°C (outside temperature compensation) |
Ingress protection | IP67 |
Durable performance | 1X10⁶ cycles (number of cycles from lower range to upper range) |
Overall weight | ≈650g (with 5m cable) |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Frequency of response | |
RS485 output | 5Hz |
4-20mA | 100Hz |
Maximum power | |
4-20mA | ≤0.02Us(W) |
RS485 | ≤0.015Us(W) |
Load characteristics | |
Current type | ≤{(Us-7.5)÷0.02(Us=supply voltage)}Ω |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH (no condensation, no condensation) |
Overload capacity | |
Overload pressure | 200%,150%FS |
Burst pressure | 500%,400%,300%FS |
Overall material | |
diaphragm | 316L stainless steel (in contact with the medium to be measured) |
Process connections | 316L stainless steel (in contact with the medium to be measured) |
enclosure | 316L stainless steel (contact) |
Core seals | Seen pressure and burst charts (contact with the medium to be measured) |
Threaded seals | Fluoroglue (in contact with the medium to be measured) |
Cable | Cable: φ5mm polyurethane shielded cable (UV protection) |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) in accordance with IEC60068-2-6 standard |
Impact Resistance: | 500g/ms meets IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | eternity |
Anti-polarity protection | No damage, but no work |
Insulation resistance | ≥100MΩ500VDC |
Dielectric Strength: | 500VAC |
Output limits | |
4-20mA | 3.8mA~26mA |
RS485 | 0~2000 |