CYYZ32Y Protective Pressure Transmitter General Industry Use Range -100kPa~0~2.5MPa Accuracy 0.25%FS 0.5%FS
The CYYZ32Y pressure transmitter adopts a double isolation diaphragm inside and an integral welding process outside, which makes it have superior anti-condensation function. It is mainly used in pressure measurement sites such as large changes in medium temperature and humid environment.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material) |
Measuring range | -100kPa~0~2.5MPa (see range selection table for details) |
Type of pressure | Gauge pressure, negative pressure |
Pressure range | -100kPa~0~2.5MPa |
Media temperature | -40~85℃ |
Response frequency | Analog signal output≤ 50Hz, digital signal output ≤5Hz |
On-time | 400ms |
Accuracy class | 0.25%FS Conventional (Range≥100kPa) 0.5%FS Conventional (10kPa≤Range<100kPa)<b15> Note: Reference conditions: temperature 25~86°C, atmospheric pressure 106~45kPa, humidity 75~<>%RH. |
Stable performance | ± 0.1% FS/year |
Overload capacity | 200% full scale |
Supply voltage | 9~36VDC |
Signal output | 4~20mA,RS485 |
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
Degree of protection | IP68 |
Durable performance | 10X10⁶ times (lower range to upper range cycles) |
Overall weight | ≈710g (including 4m cable) |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Maximum power | Current: ≤0.02Us(W) Digital: ≤0.015Us(W) |
Load characteristics | Current type: Load ≤{(Us-7.5)÷0.02}Ω (US=supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Overall material | |
Diaphragm | 316L stainless steel (contact with the medium to be measured) |
The process is connected | 304 stainless steel (contact with the medium to be measured) |
Outer shell | 304 stainless steel |
Confidential Documents | Nitrile rubber (contact with the medium to be measured) |
φ7.2mm polyurethane air shielding cable (UV protection) | |
Mechanical stability | |
10g(20… 2000Hz) conforms to IEC60068-2-6 standard | |
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength | 500VAC |
limit | |
4-20mA | 4mA~20mA |
RS485 | 0~2000 |