CYYZ51AY Flat Film Type Pressure Transmitter Range -100kPa~0~6MPa Paper Industry Viscous And Colloidal Media Pigments
The CYYZ51AY pressure transmitter was born for measuring viscous or colloidal media. The design of the pressure hole is canceled, which effectively prevents the blocking of the pressure hole, and it also has the advantages of output signal, range range, pressure interface, electrical connection and other diversification, which is convenient to match different working conditions.
Base parameters | |
Measuring medium | Liquids, fluids, gases (compatible with contact materials) |
Measuring range | -100kPa~0~6MPa (see range selection table for details) |
Type of pressure | Gauge pressure, absolute pressure, negative pressure |
Temperature compensation | Standard (temperature compensation -10-70°C) 0.25%FS, 0.5%FS Optional (temperature compensation -40-80°C) 0.1%FS, 0.25%FS (Note) Note: The range range is ≤ 10kPa, and the temperature compensation range is -10~70°C |
Accuracy class | 0.1%FS,0.25%FS,0.5%FS |
Response frequency | 5Hz,30Hz,100Hz |
Stable performance | ± 0.1% FS/year |
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
Overall weight | No display≈ 190g has a display ≈ 270g |
Degree of protection | IP65 (no display) IP54 (with display) Note: The above protection level refers to the electrical connection is achieved after the electrical connection is complete |
Output power | |
Output signal | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,0.5~2.5VDC |
Power supply range | 9~36VDC,15~36VDC,3~5VDC |
Power range | |
Voltage type | ≤0.02Us(W),≤0.008Us(W),≤0.001Us(W) |
Current type | ≤0.02Us(W) |
Digital | ≤0.02Us(W),≤0.015Us(W) |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | No display load≤{(US-7.5)÷0.02}Ω with display load≤{(US-12)÷0.02}Ω (US=supply voltage) |
Environmental conditions | |
Media temperature | -40~85℃ |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Overload capacity | |
Overload pressure | 300%FS,200%FS,12kPa,50kPa,300kPa,480kPa,750kPa,800kPa,1.2MPa,2MPa,3MPa,5MPa |
Burst pressure | 600%FS,500%FS,400%FS,20kPa,200kPa,600kPa,900kPa,1.25MPa,2MPa,3MPa,5MPa,9MPa,12.5MPa |
Overall material | |
diaphragm | 316L stainless steel (contact with the medium to be measured) |
Process connection | 304 stainless steel (contact with the medium to be measured) |
enclosure | 304 stainless steel |
Seals | Nitrile rubber (contact) fluoroelastomer (seen pressure and blasting chart (contact with the medium to be measured) |
Display the shell | ABS Engineering Plastics (LED Display) |
Hirschmann joints | ABS engineering plastics |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard |
Impact resistance: | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ500VDC |
Dielectric strength: | 500VAC |
Output limits | |
The output is minimal | 4mA,0,0.001VDC,0.05VDC |
Output maximum | 20mA,2000,10VDC,5VDC |