CYYZ71CY Anti-Corrosion Pressure Transmitter Range -0.1~0~10MPa Output 4~20mA, 4~20mA HART, RS485 Accuracy 0.5%FS
The CYYZ71CY-resistant pressure transmitter with ceramic core and process connection made of PVDF is suitable for measuring corrosive gases or liquids and for oxygen applications at low pressures. It also has a variety of explosion-proof function options, intrinsically safe type, dust intrinsically safe type, range range, electrical connection and other diversified advantages, and can also choose HART protocol communication, convenient for different working conditions on site.
Basic parameters | |
Measuring medium | Liquids or gases (compatible with contact materials) |
Pressure range | -0.1~0~6MPa (see range selection table for details) |
Pressure mode | Gauge pressure |
Medium temperature | -40~85℃ |
Turn-on time | 20ms |
Accuracy class | 0.5%FS (Reference temperature 15~25°C, atmospheric pressure 86~106kPa, humidity 45~75%RH) |
Stable performance | ±0.2% FS/year |
Temperature drift | ±0.02%FS/℃ |
Explosion-proof type | Intrinsically safe Ex ia II.C T6 Ga (4~20mA/4~20mA HART output only) Ex iaD 20 T80°C (4~20mA/4~20mA HART output only) Note: Intrinsically safe must be powered by a safety barrier or intrinsically safe power supply |
Ingress protection | IP66 Note: The above protection level refers to the level achieved when the electrical connection is complete |
Durable performance | 1X10⁶ cycles (number of cycles from lower range to upper range) |
Frequency of response | 30Hz |
Overall weight | No ≈ 1kg with 1.2kg with ≈ |
resolution | Analog output 0.02%FS, digital output 0.05%FS |
Output power | |
Output signal | 4~20mA,RS485,4~20mA HEART |
Power supply range | 9~32VDC,15~32VDC,15~24VDC |
Power range | |
Current type | ≤0.02Us(W) |
Digital | ≤0.02Us(W),≤0.015Us(W) |
Load characteristics | |
Current type | No display load ≤{(Us-7.5)÷0.02}Ω With display load ≤{(Us-12)÷0.02}Ω (Us=supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH (no condensation, no condensation) |
Overload capacity | |
Overload pressure | 150%FS |
Burst pressure | 400%FS,300%FS,300%FS,200%FS |
Overall material | |
diaphragm | Ceramics (in contact with the medium to be measured) |
Process connections | PVDF polyvinylidene fluoride (in contact with the medium to be measured) |
enclosure | Die-cast aluminum |
Core seals | Seen pressure and burst charts (in contact with the medium to be measured) |
Threaded seals | Fluoroglue |
Display window | ≈6mm explosion-proof glass |
Mechanical stability | |
Vibration resistance | 10g(20… 2000Hz) in accordance with the IEC60068-2-6 standard |
Impact Resistance: | 500g/ms meets IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Reverse polarity protection | No damage, but no work |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric Strength: | 500VAC |
Output limits | |
The output is minimal | 4mA,0,3.8mA |
The output is maximum | 20mA,2000,22mA |