CYYZ55CY Flat Film Type Pressure Transmitter Range -100kPa~0~6MPa Accuracy 0.1%FS 0.25%FS 0.5%FS Paper Industry
The CYYZ55C pressure transmitter was born for measuring viscous or colloidal media. The design of the impulse hole is eliminated, which effectively prevents the blockage of the impulse hole. It has a variety of explosion-proof function options, intrinsically safe explosion-proof, isolation explosion-proof, intrinsically safe dust explosion-proof, and can also choose HART protocol communication, cost-effective. It also has diversified advantages such as output signal, range and pressure interface, which is convenient to match different working conditions.
Base parameters | ||||||||||
Measuring medium | Liquids, fluids, gases (compatible with contact materials) | |||||||||
Pressure range | -100kPa~0~6MPa (see range selection table for details) | |||||||||
Pressure mode | Gauge pressure | |||||||||
Media temperature | -40~85℃ | |||||||||
On-time | 20ms | |||||||||
Stable performance | ± 0.1% FS/year | |||||||||
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) | |||||||||
Ex type | Flameproof Ex d II. C T6 Gb Flameproof Dust Type Ex tb IIIC T80°C Db Intrinsically Safe Ex ia II.C T6 Ga (4~20mA/4~20mA HART output only) Dust intrinsically safe Ex iaD 20 T80°C (4~20mA/4~20mA HART output only). NOTE: Intrinsically safe must be powered by a safety barrier or intrinsically safe power supply | |||||||||
Degree of protection | IP66 Note: The above protection level refers to the electrical connection achieved after the electrical connection is complete | |||||||||
Durable performance | 10X10⁶ times (lower range to upper range cycles) | |||||||||
Response frequency | Analog signal output≤ 30Hz digital signal output≤ 5Hz HART communication ≤10Hz | |||||||||
Overall weight | No display≈ 1.25kg with display ≈1.4kg | |||||||||
resolution | Analog output 0.01%FS, digital output 0.05%FS | |||||||||
Output power | ||||||||||
Power supply range | 9~32VDC,13~32VDC,15~32VDC,15~24VDC | |||||||||
Current type | ≤0.02Us(W) | |||||||||
Load characteristics | ||||||||||
Current type | Load ≤{(Us-7.5)÷0.02}Ω (US=Supply voltage) | |||||||||
HART current type | Load ≤ {(Us-12)÷0.02}Ω(Us=Supply voltage) | |||||||||
Environmental conditions | ||||||||||
Ambient temperature | -40~85℃ | |||||||||
Ambient humidity | 0%~95%RH(no condensation, no condensation) | |||||||||
Overall material | ||||||||||
diaphragm | 316L stainless steel (contact with the medium to be measured) | |||||||||
Process connection | 304 stainless steel (contact with the medium to be measured) | |||||||||
enclosure | Die-cast aluminum | |||||||||
Seals | Seen pressure and blasting charts (contact with the medium being measured) | |||||||||
Display window | ≈ 6mm explosion-proof glass | |||||||||
Mechanical stability | ||||||||||
Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard | |||||||||
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard | |||||||||
Electrical protection | ||||||||||
Short-circuit protection | perpetual | |||||||||
Anti-polarity protection | No damage, but not working | |||||||||
Insulation resistance | ≥100MΩ 500VDC | |||||||||
Dielectric strength | 500VAC |