The CYYZ96Y compact pressure transmitter is well designed and compact, making it ideal for industrial equipment with limited installation space.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material) |
Measuring range | 0~2.5~10MPa |
Pressure mode | Sealing pressure (zero point with absolute pressure 101.3kPa) |
Output signal | 0.5~3VDC |
Power supply range | 5(±0.25)VDC |
Media temperature | -40~85℃ |
On-time | 20ms |
Response frequency | Analog signal output≤ 20Hz |
Accuracy class | 0.25%FS (including repeatability≤0.02%FS, hysteresis ≤0.02%FS) Reference conditions: temperature 15~25°C, atmospheric pressure 86~106kPa, humidity 45~75%RH |
Temperature compensation | -40~85℃ |
Stable performance | ±0.2% FS/year |
Temperature drift | ±0.01%FS/℃ |
Degree of protection | IP66 |
Durable performance | 1X10⁶ times (lower range to upper range number of cycles) |
Overall weight | ≈ 30g cable≈ 15g/m |
Maximum power | ≤0.008Us(W) Note: Us=supply voltage. |
Load characteristics | Voltage type≥ 10kΩ |
resolution | 0.02%FS |
Environmental conditions | |
Ambient temperature | -40~85°C(no condensation, no condensation) |
Overpressure and blasting | |
Overload pressure | 200%FS |
Burst pressure | 500%FS,400%FS |
Overall material | |
diaphragm | 316L stainless steel (contact with the medium to be measured) |
Process connection | 316L stainless steel (contact with the medium to be measured) |
enclosure | 304 stainless steel |
Cable material | φ3.2 polyurethane shielded cable |
Mechanical stability | |
Seismic performance | 20g(20… 2000Hz) conforms to IEC60068-2-6 standard |
Impact resistance: | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength: | 500VAC |