The CYYZ93Y pressure transmitter is well designed, not only compact, but also has a high response frequency of 2kHz, which is very suitable for industrial equipment with limited installation space, and is cost-effective.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material) |
Pressure range | 0~1.6~60MPa |
Pressure mode | Sealing pressure (zero point with absolute pressure 101.3kPa) |
Output signal | 0.5~4.5VDC |
Power supply range | 8~28VDC |
Media temperature | -40~85℃ |
On-time | 20ms |
Response frequency | ≤2kHz |
Accuracy class | 0.5%FS (reference conditions: temperature 15~25°C, atmospheric pressure 86~106kPa, humidity 45~75%RH) |
Temperature compensation | -40~85℃ |
Stable performance | ±0.2% FS/year |
Temperature drift | ±0.02%FS/°C (temperature compensated) |
Degree of protection | IP67 |
Durable performance | 10X10⁶ times (lower range to upper range cycles) |
Overall weight | Main body≈ 22g; Cable≈ 24g/m |
Maximum power | ≤0.004Us(W) Note: Us=supply voltage |
Load characteristics | ≥10kΩ |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Overall material | |
diaphragm | 316L stainless steel (contact with the medium to be measured) |
Process connection | 316L stainless steel (contact with the medium to be measured) |
enclosure | 304 stainless steel |
Core seals | Laser welding |
Threaded seals | Copper and fluorine glue (in contact with the medium to be measured) |
Cable material | polyurethane |
Mechanical stability | |
Seismic performance | 20g(20… 2000Hz) conforms to IEC60068-2-6 standard |
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength | 500VAC |
Output limits | |
0.5~4.5VDC | Output minimum 0.48VDC, output maximum 4.8VDC |