CYYZ201CY Differential Pressure Transmitter For Industrial Applicationsmeasure Differential Pressure Value
The differential pressure transmitter type CYYZ201CY is designed for industrial applications and can measure the differential pressure value of liquids or gases. A variety of explosion-proof function options, intrinsically safe type, dust intrinsically safe type, flameproof type, flameproof dust type, and can also choose HART protocol communication, cost-effective.
Base parameters | |
Measuring medium | Liquid or gas (compatible with contact material.) |
Pressure mode | Differential pressure |
Media temperature | -40~85℃ |
On-time | 20ms |
Accuracy class | 0.25%FS (differential pressure range to rated range ratio ≥1:2.5) 0.5%FS (differential pressure range to nominal range ratio <1:2.5) With repeatability≤0.05%FS, hysteresis ≤0.05%FS Meter display accuracy 0.5%FS<b15>, liquid crystal (LCD with backlight)
Note: Reference condition temperature 25~86 °C, Atmospheric pressure 106~45kPa, humidity 75~<>%RH. |
Response frequency | Analog signal output≤ 30Hz, digital signal output ≤5Hz, HART communication ≤ 10Hz |
Stable performance | ± 0.1% FS/year |
Temperature compensation | -10~70℃ |
Temperature drift | ±0.01%FS/°C (temperature compensation range) ±0.05%FS/°C (outside temperature compensation range) |
Stable performance | ± 0.1% FS/year |
Ex type | Flameproof Ex db II.C T6 Gb Flameproof Dust Type Ex tb IIIC T80°C Db
Intrinsically Safe Ex ia II.C T6 Ga (4~20mA/4~20mA HART output only) |
Degree of protection | IP66 Note: The above protection level refers to the electrical connection achieved after the electrical connection is complete |
Durable performance | 1X10⁶ times (lower range to upper range number of cycles) |
Overall weight | No display≈ 1.51kg With display≈1.55kg |
resolution | Analog output 0.01%FS, digital output 0.05%FS |
Output power | |
output | 4~20mA,RS485,0~10VDC,0~5VDC,1~5VDC,4~20mA HART |
Power supply | 9~32VDC,13~32VDC,15~32VDC,15~24VDC |
Maximum power | |
4~20mA with/without display RS485 with display 0~10VDC with display
0~5VDC with display | ≤0.02Us(W) |
RS485 no display | ≤0.015Us(W) |
0~10VDC no display 0~5VDC no display 1~5VDC no display | ≤0.008Us(W) |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | No display load≤{(US-7.5)÷0.02}Ω with display load≤{(US-12)÷0.02}Ω (US=supply voltage) |
HART current type | Load ≤ {(Us-12)÷0.02}Ω(Us=Supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH(no condensation, no condensation) |
Overall material | |
diaphragm | 316L stainless steel (contact with the medium to be measured) |
Process connection | 304 stainless steel (contact with the medium to be measured) |
enclosure | Die-cast aluminum |
Seals | Nitrile rubber O-ring (in contact with the medium to be measured) |
Display window | ≈ 6mm explosion-proof glass |
Mechanical stability | |
Seismic performance | 10g(20… 2000Hz) conforms to IEC60068-2-6 standard |
Impact resistance | 500g/ms conforms to IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Anti-polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength | 500VAC |
Output limits | |
The output is minimal | 4mA,0,0.001VDC,3.8mA |
Output maximum | 20mA,2000,10VDC,5VDC,22mA |