The CYYZ802Y-specific pressure transmitter is packaged with a metal-based pressure-sensitive chip (sputtering film), which is designed to meet the requirements of these working conditions in the hydraulic system of construction machinery, such as serious cavitation, liquid hammer phenomenon and high pressure peak, large power fluctuation, large vibration interference, and harsh environment.
Basic parameters | |
Measuring medium | Liquids or gases (compatible with contact materials) |
Measuring range | 0~1~60MPa (see range selection table for details) |
Type of pressure | Gauge pressure |
Output signal | 4~20mA |
Supply voltage | 9~28VDC |
Accuracy class | 0.5%FS |
Medium temperature | -40~105℃ |
Turn-on time | 20ms |
Frequency of response | 1kHz |
Stable performance | ±0.2% FS/year |
Temperature compensation | -40~85℃ |
Temperature drift | ±0.01%FS/°C (within temperature compensation) ±0.03%FS/°C (outside temperature compensation) |
Overall weight | No display ≈ 190g with display ≈ 270g |
Ingress protection | See Outline & Dimensions |
Durable performance | 1X108 CYCLES (NUMBER OF CYCLES FROM LOWER TO UPPER RANGE) |
Maximum power | 0.02Us(W) Note: Us=supply voltage |
Overall weight | ≈55g |
resolution | 0.01%FS |
Load characteristics | |
Voltage type | ≥10kΩ |
Current type | Current type: ≤{(Us-8)÷0.02}Ω (Us=supply voltage) |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH (no condensation, no condensation) |
Overload capacity | |
Overload pressure | 3 times 3 times 2.5 times |
Burst pressure | 40 times 10 times and ≤ 400MPa ≤ 400MPa |
Overall material | |
diaphragm | 17-4PH stainless steel (in contact with the medium to be measured) |
Process connections | 304 stainless steel (in contact with the test medium) |
enclosure | 304 stainless steel |
ED CIRCLE | nitrile rubber |
Mechanical stability | |
Random vibration | 20g in line with GB/T2423.56-2006 |
Masahiro vibrates | 14.1g in accordance with GB/T2423.10-2008 |
impact | 500g/ms meets IEC60068-2-27 standard |
Electrical protection | |
Short-circuit protection | perpetual |
Reverse polarity protection | No damage, but no work |
Insulation resistance | ≥100MΩ500VDC |
Dielectric Strength: | 500VAC |