CWS101Y intelligent wireless temperature and humidity transmitter adopts the form of communication + power + sensor three-in-one, ready to use without considering other factors, equipped with NB-IoT module, is a low-power, wireless communication function of the intelligent instrument, combined with the big data platform can be realized in a wide range of online multifunctional monitoring.
Measuring medium | Gas (compatible with contact materials) |
Temperature range | -40~80℃ |
Humidity range | 0-100%RH(Relative humidity) |
Overall weight | ≈410g |
Stable performance | ±1%RH FS/year±0.2℃/year |
Protection level | IP65 |
Response speed | The temperature is increased by 10°C per step, the humidity is increased by 10%RH per step, and the gas flow rate is 0.1m/s |
Protocol parameters | |
Network Standard | NB-IoT |
Upload information | Data, battery level, signal strength |
Sending interval | 15min~24h/time (default is 2h/time) |
Send time | ≈12s/time |
Transmit power consumption | ≈0.5mA/time |
Collection frequency | 1 to 30 times during the sending interval (30 times by default) |
Collection time | ≈1s/time |
Power consumption | ≈0.002mA/time |
Battery parameters | |
Working power supply | 3.6V 19Ah*1 |
Battery Life | Depends on the frequency of collection and transmission (ignoring environmental and time factors). The annual dormant power consumption is 0.7Ah. For example, the transmission interval is 1h, the collection frequency is 30 times, and the battery life is ≤1.5 years. For example, the transmission interval is 2h, the collection frequency is 30 times, and the battery life is ≤3 years. |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH (no condensation and no condensation) |
Overall material | |
Main shell | ABS engineering plastics contact the measured medium |
Filters | Polyethylene (density 50μm) Contact with the measured medium |
show | LCD display with backlight |
Seals | Nitrile rubber contacts the measured medium |
Mechanical stability | |
Vibration resistance | 5g (20…2000Hz) in accordance with IEC60068-2-6 standard |
Impact resistance | 500g/ms Comply with IEC60068-2-27 standard |