CYYZ61TEY ceramic sanitary pressure transmitter is suitable for applications with sanitary requirements. The core liquid receiving part is made of ceramic, which makes it anti-stabbing, vacuum-resistant, corrosion-resistant and so on. It can measure gases, liquids, fluids or media with particles. Explosion-proof function is optional.
Measuring medium | Gas, liquid or fluid (compatible with contact materials) |
Pressure range | -0.1~0~10MPa (see range selection table for details) |
Pressure mode | Gauge pressure, absolute pressure, negative pressure |
Medium temperature | -40~85℃ |
Connection time | 20ms |
Accuracy level | 0.5%FS (reference conditions: temperature 15-25°C, atmospheric pressure 86-106kPa, humidity 45-75%RH) |
Stable performance | ±0.2% FS/year |
Temperature drift | ±0.02%FS/℃ |
Explosion-proof type | Intrinsically safe Ex ia ⅡC T6 Ga (4~20mA output only) |
Protection level | IP65 Note: The above protection level refers to the level achieved after the electrical connection is complete. |
Durable performance | # Lost Data # |
Response frequency | Analog signal output ≤30Hz Digital signal output ≤5Hz |
Overall weight | ≈300g |
Resolution | Analog output 0.02%FS, digital output 0.05%FS |
Output power supply | |
4~20mA | 9~28VDC, 15~24VDC (intrinsically explosion-proof) |
RS485 | 9~28VDC |
Maximum Power | |
4~20mA | ≤0.02Us(W) |
RS485 | ≤0.015Us(W) |
Load characteristics | |
Current Type | Load ≤{(Us-7.5)÷0.02}Ω |
Environmental conditions | |
Ambient temperature | -40~85℃ |
Ambient humidity | 0%~95%RH (no condensation and no condensation) |
Overpressure and explosion | |
Overload pressure | 200%FS, 200%FS, 200%FS, 150%FS, 200%FS, 200%FS |
Burst pressure | 400%FS, 250%FS, 250%FS, 200%FS, 400%FS, 250%FS |
Overall material | |
Diaphragm | Ceramic (contacting the measured medium) |
Process connection | 316L stainless steel (contacting the measured medium) |
shell | 304 Stainless Steel |
Core seal | See the pressure and burst chart (contact with the measured medium) |
O-Ring | Silicone rubber (contacting the measured medium) |
ED Circle | Fluorine rubber |
Hirschmann connector | ABS engineering plastics |
Mechanical stability | |
Vibration resistance | 10g (20…2000Hz) in accordance with IEC60068-2-6 standard |
Impact resistance | 500g/ms Comply with IEC60068-2-27 standard |
Electrical protection | |
Short circuit protection | permanent |
Reverse polarity protection | No damage, but not working |
Insulation resistance | ≥100MΩ 500VDC |
Dielectric strength | 500VAC |
Output Limitation | |
4~20mA | 4mA~20mA |
RS485 | 0~2000 |