Shell and Tube Heat Exchanger
Marine Condenser Water - Cooled Condenser
1, Introduction:
(1) The product is applicable to water chiller units, water source heat pump units etc.
(2) Suitable refrigerants are R22, R134a, R407C, R410A etc.
(3) Apply load cold agent for tap water, underground water, river water and sea water or brine, water and
glycol solution, sulfate solution, etc.
(4) For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel
tube, etc. Shell using seamless steel pipe, stainless steel tube, etc.
2, Heat exchange tube: two main specifications.
(1) ∅ within 5/8 "efficient copper pipe outside screw wing, ∅ 5/8" stainless steel pipe.
(2) the ∅ 3/4 "inside outside screw wing efficient copper tube, ∅ 3/4" stainless steel pipe
3, Main material, the shell of 20 # seamless steel pipe, stainless steel pipe.
4, Interface:
OIL COOLER CAPACITY
3RT TO 40RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | |||||
D | T1 | T | A | C | E | ||||
QXCF3S4 | 3 | 1.134 | 114 | 635 | 721 | 75 | 140 | 70 | 23 |
QXCF5S5 | 5 | 1.189 | 140 | 635 | 721 | 75 | 165 | 70 | 33 |
QXCF8S6 | 8 | 3.024 | 168 | 762 | 858 | 90 | 185 | 92 | 49 |
QXCF10S6 | 10 | 3.780 | 168 | 953 | 1049 | 90 | 185 | 92 | 58 |
QXCF12S6 | 12 | 4.536 | 168 | 953 | 1049 | 90 | 185 | 92 | 62 |
QXCF15S6 | 15 | 5.670 | 168 | 1270 | 1366 | 100 | 185 | 92 | 75 |
Model | S (Oil vent) | P1 (inlet/outlet oil vent) Copper pipe external diameter (inch) | W (inlet/outlet water vent) |
FPT(inner pipe thread) | FPT(inner pipe thread) | ||
QXCF3S4 | 1/2 | 5/8 | 1 |
QXCF5S5 | 1/2 | 5/8 | 1-1/2 |
QXCF8S6 | 1/2 | 7/8 | 1-1/2 |
QXCF10S6 | 1/2 | 7/8 | 1-1/2 |
QXCF12S6 | 1/2 | 1-1/8 | 1-1/2 |
QXCF15S6 | 1/2 | 1-1/8 | 1-1/2 |
CONDENSER SERIES SINGLE MACHINE CAPACITY: 40RT TO 60RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||
D | T1 | T | A | C | E | |||||
QXC40S10 | 40 | 15.12 | 273 | 1600 | 1750 | 120 | 273 | 85 | 172 | 31 |
QXC45S10 | 45 | 17.01 | 273 | 1600 | 1750 | 120 | 273 | 85 | 180 | 35 |
QXC50S10 | 50 | 18.90 | 273 | 2032 | 2182 | 120 | 273 | 85 | 209 | 38.5 |
QXC55S10 | 55 | 20.79 | 273 | 2032 | 2182 | 120 | 273 | 85 | 217 | 42.5 |
QXC60S10 | 60 | 22.68 | 273 | 2032 | 2182 | 120 | 273 | 85 | 224 | 46 |
Model | S (Vent) | P (fluoride inlet) Copper pipe diameter (inch) | L(fluoride outlet) Copper pipe diameter (inch) | W (standard port) | W (optional port) |
FPT(inner pipe thread) | FPT(inner pipe thread) | FPT(inner pipe thread) | |||
QXC40S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC45S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC50S10 | 3/8 | 1-5/8 | 1-1/8 | 3 | 2-1/2 |
QXC55S10 | 3/8 | 1-5/8 | 1-3/8 | 3 | 2-1/2 |
QXC60S10 | 3/8 | 1-5/8 | 1-3/8 | 3 | 2-1/2 |
U SHAPED TUBE DRY EVAPORATOR (SINGLE SYSTEM)
CAPACITY: 18KW TO 95KW
Models | QXU18S5 | QXU28S5 | QXU35S6 | QXU47S6 | QXU56S6 | QXU65S6 | QXU80S8 | QXU95S8 | ||
Rated data Refrigerant R22 ti=12°C te=2°C tu=7°C Dts=5°C | Qn | KW | 18.6 | 28.2 | 35.1 | 47 | 56 | 65 | 80 | 95 |
Kcal/h(×103 ) | 16 | 24 | 30.2 | 40.4 | 48.2 | 56.7 | 68.8 | 81.7 | ||
Wn | m3 /h | 4 | 6 | 6 | 8 | 9.6 | 11.4 | 13.8 | 16.4 | |
Wm | m3 /h | 6.3 | 8 | 10 | 11.4 | 12 | 14.5 | 18 | 21 | |
Dpn | bar | 0.16 | 0.29 | 0.27 | 0.41 | 0.35 | 0.39 | 0.42 | 0.46 |
Models | QXU18S5 | QXU28S5 | QXU35S6 | QXU47S6 | QXU56S6 | QXU65S6 | QXU80S8 | QXU95S8 | |
Dimension(mm) | A | 887 | 1037 | 1275 | 1407 | 1431 | 1431 | 1631 | 1781 |
B | 140 | 140 | 168 | 168 | 168 | 168 | 219 | 219 | |
C | 97 | 97 | 107 | 107 | 161 | 161 | 161 | 161 | |
D | 690 | 840 | 1040 | 1190 | 1030 | 1180 | 1380 | 1530 | |
E | 180 | 180 | 200 | 200 | 200 | 200 | 240 | 240 | |
Vent | S1 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outlet | S2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Connection | W(DN) | 40 | 40 | 50 | 50 | 65 | 65 | 65 | 65 |
D1(mm) | 22 | 22 | 22 | 22 | 22 | 22 | 22 | 22 | |
D2(mm) | 35 | 35 | 35 | 35 | 54 | 54 | 54 | 54 | |
P(kg) | 49 | 58 | 72 | 78 | 88 | 93 | 125 | 136 | |
Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow Dpn-pressure drop of recirculating cooling water Dts-overheat temperature |
COOPERATED CLENTS