Tube Heat Exchanger Water Cooling
Condenser for Industrial Chiller
Tube Heat Exchanger Water Cooling Condenser for Industrial Chiller is suitable for water cooled
unit water source heat pump, air cooled pump and air cooled heat pump unit.
The product is applying for refrigerants of R22, R134a, R407C and R410A etc.
The referigerating medium is for tap water, underground water, river water and sea water or brine, water
and glycol solution, sulfate solution, etc.
For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,
etc. The shell raw material mainly are seamless steel tube, stainless steel pipe.
1, Heat exchange tube: four main tube type.
(1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.
(2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.
(3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry
evaporator.
(4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry
evaporator.
2, shell raw material:
There are two of the major materials:
(1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.
(2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than
40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.
3, interface:
Dry type spiral baffle plate evaporator, flooded evaporator, built-in oil separator condenser, sea water
condenser, stainless steel heat exchanger, oil cooler, oil separator, gas-liquid separator and liquid
accumulator.
The spiral baffle plate evaporator is the latest product designed and made by Qiaoxin and has obtained
the national technical patents, which can save 20% in copper consumption and 30% in ferrous metals,
reach the total energy saving rate 30% after test and satisfy the national economic policy of industrial
upgrading, saving energy and reducing consumption and environmental protection.
CONDENSER SERIES DOUBLE CIRCUIT
CAPACITY: 50RT TO 200RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC50D10A | 50 | 18.9 | 273 | 953 | 2364 | 90 | 360 | 150 | 350 | 240 | 265 | 38.5 |
QXC60D10A | 60 | 22.68 | 273 | 953 | 2364 | 90 | 360 | 150 | 350 | 240 | 279 | 46 |
QXC70D12A | 70 | 26.46 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 359 | 53.5 |
QXC80D12A | 80 | 30.24 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 375 | 61 |
QXC100D12A | 100 | 37.80 | 325 | 953 | 2377 | 90 | 406 | 180 | 350 | 240 | 409 | 76 |
QXC120D12A | 120 | 45.36 | 325 | 1270 | 3011 | 120 | 406 | 180 | 350 | 240 | 481 | 91 |
QXC140D14A | 140 | 52.92 | 355 | 1270 | 3018 | 120 | 440 | 200 | 350 | 240 | 553 | 106 |
QXC160D16A | 160 | 60.48 | 426 | 1600 | 3656 | 120 | 510 | 260 | 310 | 310 | 723 | 120.6 |
QXC200D16A | 200 | 75.60 | 426 | 1600 | 3656 | 120 | 510 | 260 | 310 | 310 | 777 | 150.8 |
Model | S (Vent) | P (fluoride inlet) Copper pipe diameter (inch) | L(fluoride outlet) Copper pipe diameter (inch) | W (standard port) |
FPT(inner pipe thread) | Male flange | |||
QXC50D10A | 3/8 | 1-3/8 | 7/8 | DN65 |
QXC60D10A | 3/8 | 1-5/8 | 1-1/8 | DN65 |
QXC70D12A | 3/8 | 1-5/8 | 1-1/8 | DN80 |
QXC80D12A | 3/8 | 1-5/8 | 1-1/8 | DN80 |
QXC100D12A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC120D12A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC140D14A | 3/8 | 2-1/8 | 1-3/8 | DN100 |
QXC160D16A | 3/8 | 2-5/8 | 1-3/8 | DN125 |
QXC200D16A | 3/8 | 2-5/8 | 1-5/8 | DN125 |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 110RT TO 200RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC110S12A | 110 | 41.58 | 325 | 2500 | 2966 | 150 | 406 | 180 | 350 | 240 | 411 | 83.5 |
QXC120S14A | 120 | 45.36 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 490 | 91 |
QXC130S14A | 130 | 49.15 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 506 | 98.5 |
QXC140S14A | 140 | 52.92 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 521 | 106 |
QXC150S14A | 150 | 56.70 | 355 | 2500 | 3023 | 150 | 440 | 200 | 400 | 290 | 536 | 113.5 |
QXC160S16A | 160 | 60.48 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 637 | 120.6 |
QXC180S16A | 180 | 68.04 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 667 | 135.5 |
QXC200S16A | 200 | 75.60 | 426 | 2500 | 2952 | 150 | 530 | 260 | 310 | 310 | 697 | 150.8 |
Model | S (Vent) | P (fluoride inlet) Copper pipe diameter (inch) | L(fluoride outlet) Copper pipe diameter (inch) | W (standard port) | W (optional port) |
FPT(inner pipe thread) | Male flange | Male flange | |||
QXC110S12A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC120S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC130S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC140S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN100 |
QXC150S14A | 3/8 | 3-1/8 | 1-5/8 | DN100 | DN125 |
QXC160S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC180S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC200S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
CONDENSER SERIES SINGLE CIRCUIT
CAPACITY: 220RT TO 426RT
Model | Refrig. ton (RT) | Refrig. ton (104kcal/h) | Dimension (mm) | Weight (kg) | Max. water flow | |||||||
D | T1 | T | A | C | E | H1 | H2 | |||||
QXC220S16A | 220 | 78.55 | 426 | 2860 | 3326 | 150 | 530 | 260 | 310 | 310 | 730 | 165.8 |
QXC240S16A | 240 | 81.65 | 426 | 2860 | 3326 | 150 | 530 | 260 | 310 | 310 | 763 | 181 |
QXC260S20A | 260 | 84.36 | 480 | 3200 | 3666 | 150 | 530 | 280 | 310 | 310 | 802 | 195.5 |
QXC280S20A | 280 | 88.24 | 480 | 3200 | 3666 | 150 | 530 | 280 | 400 | 290 | 841 | 211 |
QXC320S20A | 320 | 95.21 | 480 | 3200 | 3666 | 150 | 600 | 280 | 400 | 290 | 912 | 240.6 |
QXC340S22A | 340 | 98.68 | 530 | 3500 | 3966 | 150 | 600 | 300 | 400 | 290 | 963 | 256 |
QXC380S22A | 380 | 106.53 | 530 | 3500 | 3966 | 150 | 650 | 300 | 400 | 290 | 1015 | 285.5 |
QXC426S22A | 426 | 115.62 | 530 | 3800 | 4266 | 150 | 650 | 300 | 400 | 290 | 1088 | 320 |
Model | S (Vent) | P (fluoride inlet) Copper pipe diameter (inch) | L(fluoride outlet) Copper pipe diameter (inch) | W (standard port) | W (optional port) |
FPT(inner pipe thread) | Male flange | Male flange | |||
QXC220S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC240S16A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC260S20A | 3/8 | 3-1/8 | 1-5/8 | DN125 | DN125 |
QXC280S20A | 3/8 | 4-1/8 | 2-1/8 | DN150 | DN150 |
QXC320S20A | 3/8 | 4-1/8 | 2-1/8 | DN150 | DN150 |
QXC340S22A | 3/8 | 4-1/8 | 2-1/8 | DN150 | DN200 |
QXC380S22A | 3/8 | 4-1/8 | 2-5/8 | DN200 | DN250 |
QXC426S22A | 3/8 | 4-1/8 | 2-5/8 | DN200 | DN250 |
COOPERATED CLENTS