110-172 m³/min Cost-saving Magnetic bearing-levitation centrifugal blower
Description
The impeller of the maglev blower is directly installed on the extension end of shaft, and the magnetic bearing technology is to use the electromagnetic force to suspend the rotor. At the same time, the magnetic bearing controller collects and corrects the rotor axis position signal in real time, which makes the rotor suspend and always stay in the specified position. The vibration of the rotor is greatly reduced due to the support of electromagnetic suspension bearing. The magnetic suspension centrifugal blower does not need gear speed increaser and coupling, it is directly driven by high-speed motor and controlled by the frequency converter. It has no friction and lubrication. It is more energy-saving than the traditional blower.
Features and advantages
Our Technical Advantages
Our company is based in Shanghai, China, relying on the position advantage of this economic center city, a strong technical talent team is formed by top aviation power experts and turbo machinery technology experts gathered here,focusing on turbine high technology .
At the same time, different kinds of domestic laboratories of universities, scientific research institutes, large state-owned enterprises, as well as the wisdom from overseas in energy and power field are integrated to research and develop the high-level turbo machinery which guarantees customers the superior equipment quality and worry-free installation service.
We provide machine on-site running guarantee service if necessary
MODEL | Power KW | Pressure Kpa | Air Flow m3/min | Outlet Connection | DIMENSION L*W*H mm | WEIGHT KG |
GDE75-04 | 75 | 40 | 95 | DN300 | 1780x860x1560 | 800 |
GDE75-06 | 60 | 66 | DN200 | |||
GDE75-08 | 80 | 53 | ||||
GDE75-09 | 90 | 45 | ||||
GDE100-04 | 100 | 40 | 120 | DN300 | 1980x1050x1750 | 1050 |
GDE100-06 | 60 | 85 | ||||
GDE100-08 | 80 | 68 | DN200 | |||
GDE100-10 | 100 | 55 | ||||
GDE150-04 | 150 | 40 | 180 | DN300 | 2080x1150x1850 | 1150 |
GDE150-05 | 50 | 150 | ||||
GDE150-06 | 60 | 138 | ||||
GDE150-07 | 70 | 118 | ||||
GDE150-08 | 80 | 109 | DN250 | |||
GDE150-09 | 90 | 90 | ||||
GDE200-04 | 200 | 40 | 236 | DN400 | 2280x1300x2000 | 1450 |
GDE200-05 | 50 | 192 | ||||
GDE200-06 | 60 | 162 | DN300 | |||
GDE200-07 | 70 | 150 | ||||
GDE200-08 | 80 | 135 | ||||
GDE200-09 | 90 | 115 | ||||
GDE200-10 | 100 | 108 | ||||
GDE200-12 | 120 | 100 | ||||
GDE300-05 | 300 | 50 | 288 | DN500 | 3080x1650x2100 | 2050 |
GDE300-06 | 60 | 270 | ||||
GDE300-08 | 80 | 215 | DN400 | |||
GDE300-10 | 100 | 172 | ||||
GDE300-12 | 120 | 130 | DN300 | |||
GDE300-15 | 150 | 110 | ||||
GDE400-05 | 400 | 50 | 392 | DN600 | 3350x1850x2200 | 2360 |
GDE400-06 | 60 | 335 | ||||
GDE400-08 | 80 | 270 | DN500 | |||
GDE400-10 | 100 | 230 | ||||
GDE400-12 | 120 | 195 | DN400 | |||
GDE400-15 | 150 | 160 | ||||
Remarks 1.Above Design Parameters are obtained based on below conditions: We assume the inlet volume flow is defined as the standard of 20℃ suction temperature and 1atm 2.We reserve the right to update the referred contents. Some parameters can be changed according to the actual needs. Please refer to the pre-sale service. |