Customized Structure-integrated Magnetic bearing-levitation centrifugal blower
Description
The magnetic suspension centrifugal blower is one kind of high-speed centrifugal blower, which doesn’t use the traditional gear transmission and mechanical bearing any more. The working principle of this kind of blower is to suspend the rotating shaft through the action of magnetism, with small friction resistance and high efficiency. which is convenient to use, low cost, little daily maintenance and gradually expanded market share.
To change the air volume by adjusting the rotation speed of the impeller which is controlled by a variable frequency inverter. The machine is of easy operation, low cost,little maintenance and has been more and more popular in water treatment, cement manufacturing and other related industries.
Application effect comparison with roots blower
Currently, the maglev blower has been widely used in China, with its high efficiency, energy saving, convenient maintenance and other characteristics of the user's praise. It has gradually become the mainstream equipment of sewage treatment plant.
Taking a municipal sewage plant as an example, the designed daily treatment capacity of the sewage plant is 50000 tons. The biological fluidized bed process is adopted. Four roots blowers are used in the aeration blower of the original biochemical tank, with a single air volume of 58.6m3/min, a pressure of 68.6kpa, a rated power of 132kw and an operating power of 117.3kw. The equipment has been used for many years, with rapid efficiency reduction, high energy consumption, high noise and high maintenance cost. Now, one yg100 maglev blower is used to replace the original four roots blowers, with remarkable results.
It can be seen from the above that the maglev blower has remarkable energy saving and emission reduction capacity in the actual application process, and has the characteristics of convenient maintenance, no need to be on duty, simple operation and low noise pollution. Under the trend of modernization of sewage treatment plant, maglev blower has become the first choice of aeration equipment in sewage treatment plant; at the same time, under the condition of marketization of sewage treatment industry, it not only greatly reduces the operation cost of sewage treatment plant, but also improves the comprehensive competitiveness of water plant, so as to promote the effective development of sewage treatment industry.
Our Technical Advantages
Relying on Famous Professional University in China and the resource advantages of senior compressor enterprises in Mainland China, GoodSeaA has continuously increased its R&D investment and cultivated a talent team. On the other hand, it has accelerated the connection of universities,research institutes, large state-owned enterprise technical experts and the wisdom&brain resources of foreign related fields. It has also integrated the resources between related laboratories of universities and research institutes,high precision manufacturing capacity of military supporting enterprises and other related cooperation system,focusing on the segment market of “energy power optimization", form a strong synergistic and comprehensive capabilities in energy power field,including top-level technology research and development, products, manufacturing, installation and service.
Additional Technical Service Provided by GooDSeaA
Technical Service Provided for New Project: | Customer Demand Learning - Equipment Selection - Solutions Evaluation - Engineering Design - Installation Guidance - Equipment Commissioning - After Sales Service |
Technical Service Provided for Modified Project: | Customer Demand Learning - Site Investigation - Equipment Selection - Energy Efficiency Saving Accounting - Solutions put into execution - Installation&Commissioning - Warranty Service |
Parameters of Magnetic bearing-levitation centrifugal blower
MODEL | Power KW | Pressure Kpa | Air Flow m3/min | Outlet Connection | DIMENSION L*W*H mm | WEIGHT KG |
GDE75-04 | 75 | 40 | 95 | DN300 | 1780x860x1560 | 800 |
GDE75-06 | 60 | 66 | DN200 | |||
GDE75-08 | 80 | 53 | ||||
GDE75-09 | 90 | 45 | ||||
GDE100-04 | 100 | 40 | 120 | DN300 | 1980x1050x1750 | 1050 |
GDE100-06 | 60 | 85 | ||||
GDE100-08 | 80 | 68 | DN200 | |||
GDE100-10 | 100 | 55 | ||||
GDE150-04 | 150 | 40 | 180 | DN300 | 2080x1150x1850 | 1150 |
GDE150-05 | 50 | 150 | ||||
GDE150-06 | 60 | 138 | ||||
GDE150-07 | 70 | 118 | ||||
GDE150-08 | 80 | 109 | DN250 | |||
GDE150-09 | 90 | 90 | ||||
GDE200-04 | 200 | 40 | 236 | DN400 | 2280x1300x2000 | 1450 |
GDE200-05 | 50 | 192 | ||||
GDE200-06 | 60 | 162 | DN300 | |||
GDE200-07 | 70 | 150 | ||||
GDE200-08 | 80 | 135 | ||||
GDE200-09 | 90 | 115 | ||||
GDE200-10 | 100 | 108 | ||||
GDE200-12 | 120 | 100 | ||||
GDE300-05 | 300 | 50 | 288 | DN500 | 3080x1650x2100 | 2050 |
GDE300-06 | 60 | 270 | ||||
GDE300-08 | 80 | 215 | DN400 | |||
GDE300-10 | 100 | 172 | ||||
GDE300-12 | 120 | 130 | DN300 | |||
GDE300-15 | 150 | 110 | ||||
GDE400-05 | 400 | 50 | 392 | DN600 | 3350x1850x2200 | 2360 |
GDE400-06 | 60 | 335 | ||||
GDE400-08 | 80 | 270 | DN500 | |||
GDE400-10 | 100 | 230 | ||||
GDE400-12 | 120 | 195 | DN400 | |||
GDE400-15 | 150 | 160 | ||||
Remarks 1.Above Design Parameters are obtained based on below conditions: We assume the inlet volume flow is defined as the standard of 20℃ suction temperature and 1atm 2.We reserve the right to update the referred contents. Some parameters can be changed according to the actual needs. Please refer to the pre-sale service. |