Class III IP20 1500V 3P 40kA Surge Protection Device for house use
Uc(maximum continuous operating voltage) | 1500Ucpv |
Imax(maximum discharge current) | 40kA |
In(nominal discharge current for class II test) | 20kA |
Up(voltage protection level) | ≤2.0kv |
Combination | 3P |
response time | ≤25ns |
Signal deterioration indication | Red: replace Green:ok |
Housing Material | thermoplastic material |
Housing self-extinguishing class | UL94_V0 |
Temperature range | -40℃~+80℃ |
humidity range | 5%RH~95%RH |
Elevational | ≤3000m |
Method of connecting wire | Parallel Connect |
Thread Dimensions | 4~35mm2 |
Mounting method | DIN:35mm |
IP(degree of protection of enclosure) | IP20 |
Follow up standard | IEC 61643-1,GB/T 18802.1 |
Feature:
1. Small size, easy to plug and replace
2. Fault resistant Y-type circuit, composed of three varistors and thermal tripping device in series
3. Double tripping protection device to provide more reliable protection
4. Large flow and quick response
5. Multi-function connection port can connect wire and bus bar
6. When the fault window pops open in green, and provides remote monitoring through the warning port
Installation Instructions:
1. Power must be cut off before installation, and live operation is strictly prohibited
2. It is suggested to connect the fuse or automatic short-circuit in series at the front end of the lightning protection module
3. Please connect according to the installation diagram, where + is the positive wire, - is the negative wire, and PE is the ground wire. Don't make a mistake. After the installation is completed, close the switch and check whether the working condition is normal
4. Insert the module in place after installation and check whether the lightning protection module works normally
5. During the use of SPD, it should be regularly monitored and checked the status of the fault display window. When the fault display window is red or the remote terminal output an alarm signal, it indicates that the lightning protection module has broken down and should be repaired or replaced in time
6. Lightning protection module should be installed in parallel, and the connecting line should be firm and reliable, and it should be short, thick and straight