OBV5-C40-PV
PV Heavy Duty SPDs,Type 1+2 of surge protective devices comprises a complete range of compact protectors for common and differential mode protection against transient overvoltages at the DC-side of photovoltaic power plants or TNC.
Prewired modular complete unit for use in photovoltaic systems consisting of a base part and plug-in protection modules combined disconnection and short-circuiting device with safe electrical isolation in the protection module prevents fire damage resulting from d.c. switching arcs (patented SCI principle)
Tried and tested fault-resistant Y circuit of the OBV5-C40-PV prevents damage to the surge protective device in case of insulation faults in the generator circuitIntegrated d.c. fuse allows safe replacement of protection modules without arc formation.
Technical Parameters
Model: OBV5-C40-PV | ||||||
Network voltage | 500Vdc | 600Vdc | 800Vdc | 900Vdc | 1000 Vdc | |
Max. operating voltage Uc | 530Vdc | 630Vdc | 840Vdc | 950Vdc | 1060 Vdc | |
Nominal discharge current ln | 20kA | |||||
Max. discharge current lmax | 40kA | |||||
Protection level (at In) Up | 1.8kV | 2.5kV | 2.8kV | 3.0kV | 3.2kV | |
Disconnector | ||||||
Thermal Disconnector | Internal | |||||
Mechanical characteristics | ||||||
Connection | by screw terminals: 4-25 mm2 | |||||
Disconnection indicator | 1 mechanical indicator by pole | |||||
Mounting | symmetrical rail 35 mm | |||||
Operating temperature | -40/+85°C | |||||
Protection class | IP20 | |||||
Standards compliance | ||||||
NF EN 61643-11 France | Parafoudre Basse Tension - Essais Classe II | |||||
IEC 61643-1 International | Low Voltage SPD - Test Class II | |||||
EN 61643-11 Europe | Parafoudre Basse Tension - Essais Classe II |
Feature&Benefits
1,Protect electric system and on-loading electrical apparatus from thunder and instantaneous over-voltage.
2,Protect transmission of Ethernet signals with 48V DC / 34V AC power supply circuits against
lightning induced surges.
3,Enhanced surge protection.
4,For mounting on 35mm DIN rails acc. to EN 60715.
5,It can effectively ensure the equipments work properly.
·Easy installation or retrofit.
·Din-rail mountable.
·Fail-safe /self-protected designRemote indicator (optional) with 3pin NO/NC contact.
·IP20 finger-safe designVisual indicator.
·Small foot print.
Application
●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers
Others
Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):
Type No. | Rated Voltage(V) Un | Continuous Voltage Uc(V~) | Standard Discharge Current In(KA) |
Max Discharge Current |
Protection Level(KA~) | Response Time(ns) |
DGM1(2)-D5 | 220/380 |
275/320 |
5 | 10 | 1.2 | ≤25 |
DGM1(2)-D10 | 10 | 2 | 1.6 | |||
DGM1(2)-C20 | 20 | 40 | 1.8 | |||
DGM13-B30 | 30 | 60 | .2.2 | |||
DGM3(4)-B40 | 10 | 80 | 2.4 | |||
DGM(4)-B60 | 60 | 100 | 2.8 | |||
DGM-N-PE | 220/255 | 40/60 | 60/80 | 1.2 | ≤100 |
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
It is also common for non-weather phenomena, such as transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.