Specifications
Brand Name :
Lanry
Model Number :
TF1100-CH
Certification :
ISO9000, CE, CPA,CMC
Place of Origin :
China
MOQ :
1 Unit
Price :
Negotiable
Payment Terms :
T/T
Supply Ability :
1000pcs/month
Delivery Time :
7-10 working days
Packaging Details :
carton packing 44X33X22cm 1PC/carton
Measure principle :
transit-time difference
Veolicty range :
0.01 to 12m/s
Accuracy :
Reading+/- 1%
Type :
Handheld
Temperature :
-35-200°C
Flow velocity range :
0.01 to 12 m/s, bi-directional
Description

Transit-time handheld Ultrasonic Flow meter Clamp On Type Liquid Measure TF1100-CH

Transit-time handheld Ultrasonic Flow meter TF1100-CH can directly display the velocity, level, flow rate and flow totalizer. The built-in digital memory makes sure that the data will not lose in case of power failure.

Transit-time handheld Ultrasonic Flow meter works on the transit-time method. The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges.

User can use hand to hold as well as to operate the flow meter main unit. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Transit-time handheld Ultrasonic Flow meter Clamp On Type Liquid Measure TF1100-CH Features:

1.Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.

2. Data logger function.

3. 14 hours battery (rechargeable), back-lit 4 lines display.

4. Non-invasive transducers.

5. Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

6. Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

7. Lightweight and easily transportable in box.

Applications:

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)

Petrochemical industry

Chemical industry -chlorine, alcohol, acids, .thermal oils.etc

Refrigeration and air conditioning systems

Food , beverage and pharmaceutical industry

Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.

Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc

Metallurgy and mining applications

General

● Service and maintenance

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement

- Evaluation and assessments

- Monitoring of regulating valves

- Capacity measurement of pumps

Transit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid Measurement

Specifications: Transmitter

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V Up to 14 h with fully charged internal batteries
Operating temperature -20℃ to +60℃
Housing material ABS( UL 94HB)
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Communication OCT, RS232 ,Logged data
Security Keypad lockout, system lockout
Size 212*100*36mm
Weight 0.5kg

Specifications: Transducer

Degree of protection IP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid Temperature Std. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Pipe diameter range 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Transducer Size Type S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*33(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducer Aluminum for standard temp. sensor, and peek for high temp. sensor
Cable Length Std: 5m

Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...

Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...

Dimensional Sketches

Transmitter:

Transit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid Measurement

Transducer:

Transit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid Measurement

Packing & Delivery

Transit-time handheld Ultrasonic Flow meter Clamp On Type Liquid Measure TF1100-CH

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
Transit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid MeasurementTransit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid MeasurementTransit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid Measurement

Delivery

Transit-time handheld Ultrasonic Flow meter Clamp On Type Liquid Measure TF1100-CH

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Send your message to this supplier
Send Now

Transit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid Measurement

Ask Latest Price
Brand Name :
Lanry
Model Number :
TF1100-CH
Certification :
ISO9000, CE, CPA,CMC
Place of Origin :
China
MOQ :
1 Unit
Price :
Negotiable
Contact Supplier
Transit Time Handheld Ultrasonic Flow Meter Clamp On Type Liquid Measurement

Lanry Instruments (Shanghai) Co., Ltd.

Site Member
7 Years
shanghai, shanghai
Since 2003
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
3000000-8000000
Employee Number :
50~100
Certification Level :
Site Member
Contact Supplier
Submit Requirement