Ultrasonic Open Channel Flow Meter for Water is mainly used to measure sewage plants,
sewage outfall of enterprises and institutions, city sewer flows and irrigation Channels and so on.
DOF6000 series DOF6000 Digital River Water Flow Meter consists of flow calculator, and the
integrated DOF6526 transducer to measure velocity and level at the same time.
It also can be available with 4-20mA, RS232, RS485 (Modbus) /GPRS and SD card logger outputs.
1. 20 coordinate points to describe the river’s shape of cross section.
2. One instrument can measure the velocity, depth and conductivity at same time.
3. Velocity Range : 0.02mm/s to 13.2m/s bi-directional, accuracy is ±1% R. Flow rate range is optional (0.8m/s; 1.6 m/s; 3.2 m/s; 6.4 m/s;13.2m/s).
4. Depth is measured by both the pressure sensor and ultrasonic level sensor principles.
5. With coordinate correction and pressure compensation function.
6. IP68 Epoxy-sealed body design, long time under water.
7. RS485/MODBUS output, can contact computer directly.
8. Pressure Depth Range: 0 to 10m; Accuracy: ±2mm. Ultrasonic Depth Range: 0.02-5m; Accuracy: ±1mm.
9. Measure velocity in both forward flow and back flow.
Specification:
Type: | Portable type |
IP class: | Calculator: IP66,Sensor: IP68 |
Power supply: | Calculator:220VAC&24VDC;Sensor:12VDC |
Operating temperature: | 0℃ ~+60℃ water temperature |
Calculator show: | 4.5” color LCD |
Calculator output: | 4-20mA, RS485( Modbus-RTU),Data logger,GPRS |
Sensor size: | 135mm x 50mm x 20mm (L x W x H) |
Application: | Partially Filled Pipe:200-10000mm; Open Channel: 200-10000mm |
Flow calculation: | Velocity; Totalizer |
Pipe, Channel type | Partially filled pipe, Open Channel and River, Stream |
Sensor material: | Epoxy-sealed body, Marine Grade 316 Stainless Steel Mounting Bracket |
Sensor weight: | 1kg with 15m of cable, it can extend o 100m |
Velocity range: | 20mm/s-0.8m/s; 20mm/s-1.6m/s; 20mm/s-3.2m/s (default); 20mm/s- 6.4m/s; 20mm/s-13.2m/s Bidirectional velocity capability |
Velocity accuracy: | ±1% R |
Velocity resolution: | 1mm/s |
Temperature resolution: | 0.1°C |
Depth range: | 20mm to 5m(Ultraflow 6527);20mm to 10m(ultraflow 6537) |
Cable: | The standard cable is 15m, the maximum option is 100m. |
Power usage: | 10V to 24VDC, 50µA standby, 100mA/s |
SDI-12: | SDI-12V 1.3recorder (1200 baud smart instrument channel) |
Packing & Delivery
Packing
With years of export experience along with excellent quality, advanced services and competitive
prices, Lanry has won numerous customers' trust and support.With years of export experience
along with excellent quality, advanced services and competitive prices, Lanry has won
numerous customers' trust and support.
Delivery
Standard meter: 3-7 days
Special meter: pls feel free to contact us
Express, by air, by sea can be optional.