Specifications
Brand Name :
Lanry
Model Number :
TF1100-EP
Certification :
CE ISO9000
Place of Origin :
Shanghai, China (Mainland)
MOQ :
1 Unit
Price :
Negotiable
Supply Ability :
100Unit/Units per Week
Packaging Details :
packing: 1unit/carton
Product Name :
TF1100-EP Portable Ultrasonic Flowmeter
Accuracy :
Reading+/- 1%
High Temp :
-35-200 °C
Output :
datalogger/4-20mA /RS485
Pipe diameter :
DN20-DN6000
Flow velocity range :
0.01~12m/s bi-directional
Description

Portable Ultrasonic flow meter oil flow meter portable clamp on flow meter


TF1100-EP Transit-Time Portable Ultrasonic Flowmeter can be available with 4-20mA, RS232, RS485 (Modbus) /GPRS and SD card logger outputs. TF1100-EP Transit-Time Portable Ultrasonic Flowmeter consists of flow calculator, and the integrated transducer to measure velocity and level at the same time.

The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Three pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility. This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Portable Ultrasonic flow meter oil flow meter portable clamp on flow meter Features:

1. 50-hour battery (rechargeable), back-lit 4 lines display all integrated into a rugged, watertight enclosure.

2. Data logger function.

3. Lightweight and easily transportable in box.

4. Non-invasive transducers.

5. Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.

7. The heat measurement function by configuring with paired temperature sensors.

Portable Ultrasonic flow meter oil flow meter portable clamp on flow meter Application:

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)

Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc
Metallurgy and mining applications
Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection.
Food , beverage and pharmaceutical industry
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems

Portable Ultrasonic flow meter oil flow meter portable clamp on flow meter Specifications:

Transmitter :

Measurement principle

Ultrasonic transit-time difference correlation principle

Flow velocity range

0.01 to 12 m/s, bi-directional

Resolution

0.25mm/s

Repeatability

0.2% of reading

Accuracy

±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s

Response time

0.5s

Sensitivity

0.003m/s

Damping of displayed value

0-99s(selectable by user)

Liquid Types Supported

both clean and somewhat dirty liquids with turbidity <10000 ppm

Power Supply

AC: 85-265V Up to 50 h with fully charged internal batteries

Enclosure type

Portable

Degree of protection

IP65

Operating temperature

-20℃ to +60℃

Housing material

ABS( UL 94HB)

Display

4 line×16 English letters LCD graphic display, backlit

Units

User Configured (English and Metric)

Rate

Rate and Velocity Display

Totalized

gallons, ft³, barrels, lbs, liters, m³,kg

Thermal energy

unit GJ,KWh can be optional

Communication

4~20mA,OCT, Relay, RS232, RS485 (Modbus),Logged data

Security

Keypad lockout, system lockout

Portable Ultrasonic flow meter oil flow meter portable clamp on flow meter Specifications:

Transducer:

Degree of protection

IP65 according to EN60529.(IP67 or IP68 Upon request)

Suited Liquid Temperature

Std. Temp.: -35℃~85℃ for short periods up to 120℃

High Temp.: -35℃~200℃ for short periods up to 250℃

Pipe diameter range

20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L

Transducer Size

Type S 48(h)*28(w)*28(d)mm

Type M 60(h)*34(w)*32(d)mm

Type L 80(h)*40(w)*42(d)mm

Material of transducer

Aluminum for standard temp. sensor,and peek for high temp. sensor

Cable Length

Std:5m

Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

Application pictures:

Clamp On Portable Ultrasonic Flow Meter Oil Flow Meter DN20 - DN6000 Pipe Diameter Clamp On Portable Ultrasonic Flow Meter Oil Flow Meter DN20 - DN6000 Pipe Diameter

Datasheet Download TF1100-EP transit-time portable ultrasonic flowmet...

Manual Download TF1100-EP portable flowmeter manual.pdf

Packing & Delivery

TF1100-EP Transit-Time Portable Ultrasonic Flowmeter with data logger function

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.

Clamp On Portable Ultrasonic Flow Meter Oil Flow Meter DN20 - DN6000 Pipe Diameter

Delivery

TF1100-EP Transit-Time Portable Ultrasonic Flowmeter with data logger function

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Send your message to this supplier
Send Now

Clamp On Portable Ultrasonic Flow Meter Oil Flow Meter DN20 - DN6000 Pipe Diameter

Ask Latest Price
Brand Name :
Lanry
Model Number :
TF1100-EP
Certification :
CE ISO9000
Place of Origin :
Shanghai, China (Mainland)
MOQ :
1 Unit
Price :
Negotiable
Contact Supplier
Clamp On Portable Ultrasonic Flow Meter Oil Flow Meter DN20 - DN6000 Pipe Diameter

Lanry Instruments (Shanghai) Co., Ltd.

Site Member
7 Years
shanghai, shanghai
Since 2003
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
3000000-8000000
Employee Number :
50~100
Certification Level :
Site Member
Contact Supplier
Submit Requirement