Specifications
Brand Name :
Altrasonic
Model Number :
HS-520A
Certification :
CE
Place of Origin :
CHINA
MOQ :
1 set
Price :
Negotiation
Payment Terms :
T/T, Western Union
Supply Ability :
200 Set per month
Delivery Time :
10 work days
Packaging Details :
Packed in carton firstly,and then reinforced with wooden case for outer packing
Generator :
Digital
Frequency Range :
1KHz~500kHz/1Mhz/hz
Measurement Speed :
5s/one Pass(600scan Point) Adjustable
Frequency Accuracy :
±10ppm
Phase Resolution :
0.15 Degree
Impedance Range :
1Ω~1MΩ
Power Supply :
AC100V~AC250V,50~60Hz, 30W
Application :
Ultrasonic Components/ultrasonic Device
Product feature :
Portable, 8inch screen, Full touch screen
Frequency Step :
0.1Hz~any
Description

Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

Specifications:

Specification
Performance
HS-520A
Product feature Portable, 8inch screen, Full touch screen
Dimension L24cm,W19cm,H10cm
Frequency range 1KHz~500kHz/1Mhz/hz
Measurement Index All the parameters, the graph
Measurement Accuracy < 0.5%
Measurement Speed 5s/one pass(600scan point) Adjustable
Frequency Accuracy ±10ppm
Phase Resolution 0.15 degree
Environment Temperature 10~40degree centigrade
Impedance Range 1Ω~1MΩ
Frequency Step 0.1Hz~any
Power Supply AC100V~AC250V,50~60Hz, 30W

Description:

For ultrasonic components measuring instrument, the most important is the admittance chart, logarithmic graph of the two graphics (the two graphics is the main method of qualified qualified), and more than a dozen parameters: resonance frequency Fs, the maximum conductance Gmax, bandwidth F2-F1, anti-resonance frequency Fp, quality factor Qm, free capacitance CT, dynamic resistance R1, dynamic inductance L1, dynamic capacitance C1, static capacitance C0, effective electromechanical coupling coefficient Keff.

Characteristics:

1. Large screen, full-screen touching, making the HS520A both HS70A-P(computer version) operating experience, and no cumbersome with a sense of computer operation.

2. Relies on the new powerful ARM processor data processing capacity, HS520A measurement accuracy is much higher than HS70A-D (with display version), can achieve HS70A-P(computer version) level.

3. Full-screen touch operation is more user-friendly, no longer need HS70A-D(own display version) a large number of physical buttons, thus operating instruments becomes extremely simple, the production size smaller, lighter and more portable.

4. Connecting the computer to operate as HS70V-P. The software is fully compatible, the user are no longer familiar with software operation.

5.HS520A was taken into account the needs of automated production line operation in the development time, reserved the 232interface with PLC communication and IO communication interface (replay input and output)

6. HS520A operation is no longer based on Windows system, with long-term reliable operation capacity in the production line.

Measuring:

(Note: There are differences in the relevant characteristic data of different manufacturers)

Measurement parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q can provide 12 parameter combinations

Test frequency: 100Hz~40MHz (cable length: 0m)

Vibrator level: 10mV~1Vrms (≤10MHz), 10mV~0.5Vrms (>10MHz); (UNKNOWN open), 3-bit resolution

DC offset: 0~±40V, 10mV resolution

Measurement terminal: 4-terminal configuration

Measuring range and highest resolution

Measurement parameter range maximum resolution

Basic measurement accuracy: 0.17 [%]

Level monitoring: 1mV~1 Vrms, 1μA~20mA

Gain-phase measurement

Measurement parameters: Tch/Rch (dB, linear ratio); Tch, Rch (V, dBm, dBv), θ (degrees, radians); Tch = measurement channel: Rch = reference channel, g = group delay

10Hz~100MHz, 1mHz resolution

Aperture frequency range: (group delay measurement) frequency interval 0.5 [%] ~ 100 [%]

Oscillator level: -65dBm~+15dBm, 0.1dB resolution

Measurement range: Tch/Rch: 0~±120dB, 0.001dB resolution; Tch, Rch: -107dBm~-5dBm (0dB attenuator), -87dBm~+15dBm, (20dB attenuator); 0.001dB, resolution: θ: ±180° (using phase scale extension function, continuous display of phase) 0.01° resolution; g: 0.1 ns~1 s, 0.1 ns resolution

Basic measurement accuracy: Tch/Rch: 0.1dB, 0.5°; Tch, Rch: 0.35dBm

Level Monitoring: Monitors the input level of the reference and test channels in dBm, dBV and V.

Detailed Images:

Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

Ultrasonic Quality Factor And Impedance Analyzing For Ceramic MaterialUltrasonic Quality Factor And Impedance Analyzing For Ceramic MaterialUltrasonic Quality Factor And Impedance Analyzing For Ceramic Material

Send your message to this supplier
Send Now

Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

Ask Latest Price
Watch Video
Brand Name :
Altrasonic
Model Number :
HS-520A
Certification :
CE
Place of Origin :
CHINA
MOQ :
1 set
Price :
Negotiation
Contact Supplier
video
Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material
Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material
Ultrasonic Quality Factor And Impedance Analyzing For Ceramic Material

Hangzhou Altrasonic Technology Co., Ltd

Site Member
10 Years
zhejiang
Since 1990
Business Type :
Manufacturer, Trading Company
Total Annual :
6million-10million
Employee Number :
100~200
Certification Level :
Site Member
Contact Supplier
Submit Requirement