Siemens C8-5 Microconvex Transducer/Neonatal And Pediatric Imaging
Siemens C8-5 Microconvex Transducer
1. Type:convex
2. Frequency:8-5MHz
3. Compatible system: X300/X500/G20/G50/G60
4. Application: neonatal and pediatric
5. Condition: pre-owned and original, in good working condition
6. With 60 days warranty
Other Siemens probes we can offer:
Brand | Model | Compatible System |
Siemens | 3.5C55S | G50/X150/X300 |
Siemens | 6C1HD | S2000 |
Siemens | 7.5L40A | G20/G40 |
Siemens | 7.5L75S | G20 and Prima / Adara |
Siemens | C7F2 | Antares/ X300 and X500 |
Siemens | CH4-1 | Antares |
Siemens | CH5-2 | G40/G60/X150/X300 |
Siemens | CH6-2 | Antares |
Siemens | CX5-2 | Antares/ Sonoline Elegra |
Siemens | C6-2 | CV70/ G50/G60/ X300/X500 |
Siemens | C6F3 | G50/G60 |
Siemens | C5F1 | Antares |
Siemens | C8-5 | X300 |
Siemens | P10-4 | Antares |
Siemens | PH4-1 | Antares |
Siemens | P4-2 | G50/G60/CV70/X150/X300/X500 |
Siemens | P5-1 | X300, X300PE |
Siemens | EC9-4 | G40/ X150/ X300/Antares |
Siemens | EV9F4 | X300 and Antares |
Siemens | VFX9-4 | Antares |
Siemens | VF13-5sp | Antares/X300/X500/G50/G60 |
Siemens | VFX13-5 | Antares |
Siemens | VF13-5 | X150/X300/X500/G40 /G50/G60/ Sonoline Sienna/Sonoline Elegra |
Siemens | VF13-5 | Antares |
Siemens | VF10-5 | Antares |
Siemens | 4V1C | Sequoia 512 GI, Sequoia C512, S2000 |
Siemens/Acuson | 4V1 | Sequoia |
Siemens/Acuson | 6L3 | Acuson Sequoia |
Siemens/Acuson | 8C4 | Sequoia 512 G /Sequoia C512 |
Siemens/Acuson | 8L5 | Sequoia 512 |
Siemens/Acuson | 8V5 | Sequoia |
Siemens/Acuson | 7L3 | Cypress |
Siemens/Acuson | 8V3 | Sequoia 512 /S1000 |
Siemens/Acuson | 9EVF4 | S1000/ S2000 and S3000 |
Siemens/Acuson | 9L4 | Acuson S2000/ Sequoia/Sequoia C512 |
Siemens/Acuson | 10V4 | Sequoia |
Siemens/Acuson | 15L8W | Sequoia 512 |
Siemens/Acuson | 15L8 | Sequoia |
Siemens/Acuson | 17L5HD | Sequoia 512 |
Siemens/Acuson | 18L6HD | S1000, S2000, S3000 |
Siemens/Acuson | AUX CW | Cypress / Cypress CV System |
Siemens/Acuson | C3 | Aspen |
Siemens/Acuson | EC9-4 | G40/ G60/X150/ X300 |
Siemens/Acuson | EC7 | Aspen/ XP128 |
Siemens/Acuson | EV-8C4 | Sequoia 512/ S2000 |
Siemens/Acuson | EC-10C5 | Sequoia 512 |
Siemens/Acuson | L5 | Aspen |
Siemens/Acuson | L7 | Aspen/128XP-10 |
Siemens/Acuson | TE-V5M | Sequoia/ Sequoia C512/Sequoia 512/ Aspen/ Cypress/S1000/S2000 |
Siemens/Acuson | TE-V5Ms | Cypress/Sequoia/S2000/X300 systems |
Siemens/Acuson | V4 | Aspen/ XP |
Siemens/Acuson | V7 | Aspen/ XP |
Knowledge point
Color Doppler flow imaging
Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.