Repair Hitachi HI VISION Avius CONT-B Board (P/N: 7513734A)
1. Repair time: 2-4 days
2. Warranty: 60 days
3. Part number: 7513734A/7513734
4. Compatible with Hitachi HI VISION Avius
Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range.
Other ultrasound parts related to Hitachi that we can offer:
Brand | Model | Description |
Hitachi | EUB-5500 | CW Doppler board EZU-ST5 |
Hitachi | EUB-5500 | MAP-A WU8012-2 |
Hitachi | EUB-5500 | MAP WB8002-A |
Hitachi | EUB-5500 | Control Panel KB319385-E6 |
Hitachi | EUB-5500 | PCB CZ08AB-S12 |
Hitachi | EUB-5500 | power board P.S. HM-071CE 7216682B HM-071K |
Hitachi | EUB-5500 | DBF board CZ04AM-S11 CZ04AB-S10 |
Hitachi | EUB-6000 | Control Panel KA182319C |
Hitachi | EUB-6000 | AC power board HM750D |
Hitachi | EUB-6000 | BWDSC board CU6045-B EF360518 |
Hitachi | EUB-6500 | TI board CZF4AB-S11 CZ04AG-S11 |
Hitachi | EUB-6500 | DBF-B CUH003-S11 |
Hitachi | EUB-6500/EUP7500 | CW Doppler board CU8019-S12 UOF672 |
Hitachi | EUB-7000 | power board |
Hitachi | EUP-8500 | control panel KB319385-A5 |
Hitachi | EUP-8500 | BE1 ASSY CU8022-S11 |
Hitachi | EUP-8500 | AWP-A1TI board CZ04AL-S10 |
Hitachi | EUP-8500 | PCB CZ08AB-S11 |
Hitachi | EUP-8500 | CONT-B CU6055-S11 |
Hitachi | EUB-6500/EUB-7500/EUB-8500 | BE1X Board 7512670A 9718091497 |
Hitachi | HI VISION Avius | RDBF 7513907A |
Hitachi | HI VISION Avius | cell board 7345930A |
Hitachi | HI VISION Avius | CONT-B/AVI board 7513734A |
Hitachi | HI VISION Avius | monitor OFTD1255 |
Hitachi | HI VISION Avius | track ball FLT20PFB-H2 |
Hitachi | HI VISION Avius | DVI EZU-DCP3 |
Hitachi | HI VISION Preirus | numeric keyboard |
Hitachi | HI VISION Preirus | DBF board CZK4AA |
Hitachi | HI VISION Preirus | RX board CZH4AA |
Hitachi | HI VISION Preirus | TX1 7513629A |
Hitachi | HI VISION Preirus | PC mainboard PDS-BX13E0678 |
Hitachi | HI VISION Preirus | CONT board CZ84AH-S11 |
Hitachi | HI VISION Preirus | power board EZU-MT28-S1 |
Hitachi | Logis HI Vision E | control panel |
Hitachi | Arietta 60 | TX board |
Hitachi | Arietta 60 | RX board |
Hitachi | Arietta 60 | CELL board |
Hitachi | Arietta 70 | TX board EP572300AA |
Hitachi | Arietta 70 | RX board EP572900 EP572200 |
Hitachi | Arietta 70 | CELL board |
Hitachi | Ascendus | TX board |
Hitachi | Ascendus | CELL board 7352830A |
Importance of maintaining ultrasound machine
Paying attention to preventive maintenance is the basic requirement of medical equipment engineers and technicians. Perform regular checks on equipment to ensure safe and effective operation of equipment, reduce downtime and save maintenance costs. Eliminate minor faults and avoid causing major faults to affect the normal operation of the hospital. Attention should be paid to any abnormality that occurs during the operation of the equipment. Sometimes a small abnormal phenomenon may be a precursor to a failure. If it is not checked, it may cause a greater failure and bring unnecessary losses to the hospital. Do not let the equipment work with faulty. Do not wait until the equipment is completely paralyzed before repairing. Routine maintenance can extend the service life of the equipment and improve economic efficiency.
Precautions for Maintenance
Before delivery, we'd like to confirm the below details of your defective ultrasonic board.
Have your board ever repaired? ( Better to be never repaired)
Is the board original in complete condition?
What's the detailed faults? ( Send me fault description, fault image or video)
Your answers will help our repair engineers team to prejudge whether it's repairable.