Philip CV650/CV850 Probe Interface Board
1.Part number: 453561814481
2.Pre-owned original one ,in excellent condition
3.We provide 60 days warranty
Various GE/Siemens/Toshiba/Hitachi/ Biosound/Medison ultrasonic boards are within our repair/ maintenance range.
Other ultrasound parts related that we can offer:
Brand | Machine type | Part type | Part number |
Philip | CX50 | Mainboard | 453561368033/453561622163/453561495832/453561239048 |
CX50 | Channel board | 453561473231/453561239066/ 453561662431 | |
CX50 | Power Supply board | 453561375144/453561384831/453561473243/453561473241 | |
Affiniti 50/Affiniti 70 | ACQ acquisition control board | 4535161610416/4535161610426 | |
EPIQ 5/EPIQ 7 | ACQ Acquisition Module board | 453561798362/453561704244/453561704245 | |
iU22/iE33 | CB Board (Channel Board) | 453561156014/453561164271/453561287451/453561303902 | |
iU22/iE33 | AIM Board | 453561210241/453561210321/453561160675/453561160672/453561210243 | |
iU22/iE33 | FEC (Front End Controller) | 453561278261/453561278266/453561464291/453561153751 | |
iU22/iE33 | EMB (excelsior motherboard) | 453561419431/453561382231/453561419431 |
Knowledge Point
CV650/CV850 Control Panel Module Board
1. Overview
CV650 and CV850 are widely used in medical imaging diagnosis. The probe interface board is a key component in these systems and is responsible for connecting and processing the signals from the probe, ensuring the accurate transmission and display of image data.
2. Functions and characteristics
Signal transmission: The probe interface board is responsible for converting the ultrasonic signal collected by the probe into a digital signal and transmitting it to the main processing unit of the system for processing.
Compatibility: Depending on the type of probe, the probe interface board needs to have good compatibility to ensure stable connection and signal transmission with various probes.
Stability and reliability: As an important part of the system, the probe interface board needs to have a high degree of stability and reliability to ensure that there is no failure or signal interruption during prolonged use.
3. Maintenance and replacement
Maintenance service: If the probe interface board fails, it is recommended to contact the official after-sales service center or maintenance organization for professional maintenance. These institutions usually have professional maintenance technology and spare parts support to provide efficient and reliable maintenance services.
Precautions: When replacing the probe interface board, ensure that the device is replaced according to the operating instructions and safety regulations to avoid damage to the device or potential security risks caused by improper operations.
4. Precautions
When using color ultrasonic diagnostic systems such as CV650/CV850, the various components of the equipment, including the probe interface board, should be regularly maintained and checked to ensure the normal operation of the equipment and image quality.
For non-professionals, it is not recommended to disassemble or repair equipment parts by themselves, so as not to cause unnecessary damage to the equipment or affect the warranty service of the equipment.
We provide professional ultrasonic plate repair services.10+years of professional maintenance service team.
If you need any product, please feel free to contact us.
Various Ultrasound Systems that we served
GE Ultrasound System |
LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON S8, VOLUSON P8, VOLUSON S6, VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ 5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7... |
Hitachi-Aloka Ultrasound System |
F31, F37, SSD-3500, SSD-3500, SSD-4000, SSD-5000, ALPHA 5, ALPHA 6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60, Arietta 70, Ascendus... |
Siemens Ultrasound System |
S2000,S3000,SC2000,X300,P500,OXana,Juniper,Omini... |