Programmable Environmental Test Chamber Constant Temperature For Humidity Testing
● THC Series of Programmable Constant Temperature and Humidity Testing Chamber are designed to accurately produce the temperature and humidity conditions required for applications such as stability studies, package testing, TAPPI, MIL-SPEC and vapor transmission.
● It is applied to test for the industries of pharmaceutical development and manufacturing, electronic components, food, semiconductor, paper and pulp, and wherever precise humidity and temperature replications are required.
● THC microprocessor controller TH500 is a user-friendly system that provides optimum accuracy and control. The display is equipped with direct readings in both temperature and humidity. It also features 100--segment programming for automatic cycling and ramping and soaking excursions. High-low or deviation alarms as well as digital communications ports are standard features.
THC Specification:
Model No. | PTH-80A | PTH-150A | PTH-225A | PTH-416A | PTH-800A | PTH-1000A | PTH-80A | PTH-150B | PTH-225B | PTH-416B | PTH-800B | PTH-1000B | |||
Internal Dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | 400 | 500 | 500 | 700 | 1000 | 1000 | ||
H | 500 | 600 | 750 | 850 | 1000 | 1000 | 500 | 600 | 750 | 850 | 1000 | 1000 | |||
D | 400 | 500 | 600 | 700 | 800 | 1000 | 400 | 500 | 600 | 700 | 800 | 1000 | |||
External Dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | ||
H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | |||
D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | 810 | 910 | 1120 | 1210 | 1310 | 1510 | |||
Volume (L) | 80 | 150 | 225 | 416 | 800 | 1000 | 80 | 150 | 225 | 416 | 800 | 1000 | |||
Temperature Range | 0℃~100℃(150℃) | -20℃~100℃(150℃) | |||||||||||||
The Evenness Of Humiture Distribu tion | ±0.5℃ ±3%RH | ± 1 ℃ ± 5 %R H | ±0.5℃ ±3%RH | ± 1 ℃ ± 5 %R H | |||||||||||
Temperature Rising Speed | 0℃~100℃ about 20min | -20℃~100℃ about 35min | |||||||||||||
Temperature Falling Speed | 20℃~0℃ about 20min | 20℃~20℃ about 45min | |||||||||||||
Freezing System | 1PC of fully sealed air cooling system | ||||||||||||||
Humidity Range | 20%~98%RH | ||||||||||||||
Humiture Stability | ±0.2℃ ±2%RH | ||||||||||||||
Humiture Adjustment | Auto balancing temperature and humidity adjustment | ||||||||||||||
Outside Materials | Stainless steel sus # 304 | ||||||||||||||
Inside Materials | Stainless steel sus # 304 | ||||||||||||||
Humidifying System | Surface evaporation, humidifier with stainless steel heating and equipped with a power off device when humidifier wants water and an over-temperature protection device. | ||||||||||||||
Thermal Material | Heat preserved by rock wool and hardened pu foaming | ||||||||||||||
Heating System | Heater with stainless steel dissipation | ||||||||||||||
Circulatory Syste m | Convection by fan forced circulatory system | ||||||||||||||
Dehumidifying System | Freezing dehumidifying system | ||||||||||||||
Water Supplying System | The advance water tank, fully automatic water supplying control, device for reuse through recovery and circulatory filtering plus a warning device for insufficient water. | ||||||||||||||
Safety Devices | Leakage and overload protection device, compressor overload protection device, power off device for over-temperature and over humidity, water insufficient protection device, overtemperatureprotection device for humidifier and the protection device for limit of temperature. | ||||||||||||||
Standard Delivery | Two sets of the adjustable SS plate, the vacuum glass windows, the test hole, a lamp inside the operation room and a movable indicator. | ||||||||||||||
Optional Accessories | Recorder | ||||||||||||||
Power | AC220V/50, AC110V/60HZ |
THC Specification:
Mode | PTH-80C | PTH-150C | PTH-225C | PTH-416C | PTH-800C | PTH-1000C | PTH-80D | PTH-150D | PTH-225D | PTH-416D | PTH-800D | PTH-1000D | ||
Internal Dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | 400 | 500 | 500 | 700 | 1000 | 1000 | |
H | 500 | 600 | 750 | 850 | 1000 | 1000 | 500 | 600 | 750 | 850 | 1000 | 1000 | ||
D | 400 | 500 | 600 | 700 | 800 | 1000 | 400 | 500 | 600 | 700 | 800 | 1000 | ||
External Dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | ||
D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | 810 | 910 | 1120 | 1210 | 1310 | 1510 | ||
Volume (L) | 80 | 150 | 225 | 416 | 800 | 1000 | 80 | 150 | 225 | 416 | 800 | 1000 | ||
Temperature Range | -40℃~100℃(150℃) | -70℃~100℃(150℃) | ||||||||||||
The Evenness Of Humiture Distribution | ±0.5℃ ±3%RH | ± 1 ℃ ± 5 %R H | ±0.5℃ ±3%RH | ± 1 ℃ ± 5 %R H | ||||||||||
Temperature Rising Speed | -40℃~100℃ about 40min | -70℃~100℃ about 60min | ||||||||||||
Temperature Falling Speed | 20℃~40℃ about 60min | 20℃~70℃ about 90min | ||||||||||||
Freezing System | 2PCS of fully sealed air cooling syste m | 3PCS of fully sealed air cooling system | ||||||||||||
Humidity Range | 20%~98%RH | |||||||||||||
Humiture Stability | ±0.2℃ ±2%RH | |||||||||||||
Humiture Adjustment | Auto balancing temperature and humidity adjustment | |||||||||||||
Outside Materials | Stainless steel sus # 304 | |||||||||||||
Inside Materials | Stainless steel sus # 304 | |||||||||||||
Humidifying System | Surface evaporation, humidifier with stainless steel heating and equipped with a power off device when humidifier wants water and an over-temperature protection device. | |||||||||||||
Thermal Material | Heat preserved by rock wool and hardened pu foaming | |||||||||||||
Heating System | Heater with stainless steel dissipation | |||||||||||||
Circulatory Syste m | Convection by fan forced circulatory system | |||||||||||||
Dehumidifying System | Freezing dehumidifying system | |||||||||||||
Water Supplying System | The advance water tank, fully automatic water supplying control, device for reuse through recovery and circulatory filtering plus a warning device for insufficient water. | |||||||||||||
Safety Devices | Leakage and overload protection device, compressor overload protection device, power off device for over-temperature and over humidity, water insufficient protection device, overtemperatureprotection device for humidifier and the protection device for limit of temperature. | |||||||||||||
Standard Delivery | Two sets of the adjustable SS plate, the vacuum glass windows, the test hole, a lamp inside the operation room and a movable indicator. | |||||||||||||
Optional Accessories | Recorder | |||||||||||||
Power | AC220V/50, AC110V/60HZ |