LCD Double Digital Display with Backlight EP Series Digital Force Gauge
Features
1. LCD double digital display with backlight;
2. USB interface; hot swappable.
3. Free setting of fracture alarm value, and upper/lower offset; selection of fracture alarm, alarm for not excess of limit, and alarm for excess of limit. When alarm values are exceeded, the buzzer acts while the display shows alarm information. The two SC open-collector level outputs drive the DC 12V relay or the solenoid to act, each output being 50mA. To use output ports, connect the power adapter first.
4. Display can be rotated 180°.
5. Enable automatic unit conversion: N, kgf, and lbf.
6. Peaks can be held or cleared; clearing time can be set.
7. A maximum of 10 groups of test reports can be saved permanently. The saved content includes peak, and average valley.
8. Shutdown and backlight can be set to perform automatically.
9. Relying on the PC dedicated test software, the force gauge can realize unlimited storage, transmission, and reproduction of test curve data.
10. Installed on different test benches, the force gauge can implement various tests.
Specifications and Parameters (for Embedded Products).
Model | EP-2N | EP-5N | EP-10N | EP-20N | EP-50N | EP-100N | EP-200N | EP-500N |
Range | 2N | 5N | 10N | 20N | 50N | 100N | 200N | 500N |
Calibration | 0.001N | 0.001N | 0.005N | 0.01N | 0.01N | 0.05N | 0.1N | 0.1N |
Calibration of Pressure | 0.01Mpa | 0.1Mpa | 1Mpa | |||||
Sensor | Embedded sensor | |||||||
Measuring Range | 1%~100% F.S | |||||||
Indication Error | ±0.5% F.S | |||||||
Units | N,kg,lb | |||||||
Display | LCD | |||||||
Working Temperature | 20±10℃ | |||||||
Relative Humidity | 15%~80%RH | |||||||
Working Conditions | No vibration sources or corrosive materials exist. | |||||||
Weight | 1kg |
Specifications and Parameters (for External Products)
Indication Error | Measuring Range | Sense | Calibration | Range | Model |
±1% F.S (depending on the sensor configured) | 1%~100% F.S | External S-shaped sensor | 0.5N | 1000N | EP-1K |
1N | 2000N | EP-2K | |||
1N | 5000N | EP-5K | |||
0.005kN | 10kN | EP-10K | |||
0.01kN | 20kN | EP-20K | |||
0.01kN | 50kN | EP-50K | |||
0.05kN | 100kN | EP-100K | |||
External spoke sensor | 0.1kN | 200kN | EP-200K | ||
0.1kN | 500kN | EP-500K | |||
0.5kN | 1000kN | EP-1000K | |||
1kN | 2000kN | EP-2000K |
Interfaces and Their Functions
1. Number of Peak saved;
2. The values Meaning of the Peak window shows:
A) PEAK:Manual Peak Clear;
B) PEAK ATUO:Automatic peak Clear;
C) PEAK AVER:Average peak of the Saved peak data group;
D) PEAK MAX: maximum peak of the Saved peak data group;
E) PEAK MIN:minimum peak of the Saved peak data group;
3. Display the peak value hold and real time value;
4. Battery icon;
5. The online with computer software symbol;
6. Measuring unit;
7. Push(compression) sign;
8. Pull(tension) sign;
9. Alarm indicator:
F) “—”the display value is less than the lower force limit;
G) “○”Be tested or Fracture, end the test;
H) “+”the display value is greater than the upper force limit;
Buttons and Their Functions
Button | Standalone Test Mode | Online Test Mode | Storage & Query Mode | Menu Operation Mode |
![]() | Shutdown | Shutdown | Invalid | Invalid |
![]() | Unit conversion | Invalid | Exit | Quit parameter modification or exit |
![]() | Zero set | Zero set | Clear peak value of flashing number | Data cleared |
![]() | Test output | Invalid | output peak value test report
| Up |
![]() | Enter storage & query mode | Invalid | Switch to upper window | Down |
![]() | Enter parameter setting mode | Invalid | Invalid | Confirm parameter modification |
![]() | Peak value saved | Peak value saved | Move the blinking number leftward by one unit | |
![]() | Peak clearing | Peak clearing | Move the blinking number rightward by one unit |