20kva igbt online ups 3 phase online industrial ups 20kva online ups nepal
High Frequency Online Ups
Technical Specifications:
1.True Online UPS with Triple Conversion
2.Wide Input Voltage Range
3.Built-in OVCD for High Voltage Protection
4. Active Input Power Factor Corrector
5.Selectable Output Voltage
6. output power factor 0.8
7. Built-in and External Battery Options
8. Advanced battery management (ABM)
9. Smart Battery Charger Design
10. Comprehensive Display for easy monitoring and access of UPS Status
11.Generator Compatible
12. Cold start feature (DC power on)
13. RS232/USB/SNMP (LAN) for UPS monitoring
14. ECO mode operation for energy saving
15. Self-diagnosis at UPS start ups
Applications
-Graphic Workstations
-Network servers
-Data Processing centers
-Data warehouses
-BPOs
-Telecommunication
-Networking Equipment.
-Mini and Micro Computers
-Medical equipment
Technical Parameters:
Model*1 | HP1106B | HP1106H | HP1110B | HP1110H | HP3110H | HP3115H | HP3120H |
rated power | 6KVA/5.4KW | 10KVA/9KW | 15KVA/13.5KW | 20KVA/18KW | |||
Input and output modes | Single phase in single phase out | Three phase in single phase out | |||||
Electrical Characteristics | |||||||
Product topology | On-line double conversion | ||||||
Input voltage | 220/230/240V | ||||||
Input voltage range | 120-275V,176-270V Full power operation | ||||||
Output Voltage / Output Distortion | 220V/230V/240V ±1 %, THDU<3% | ||||||
Enter the frequency range | 45Hz-64Hz, 50/60Hz Adaptive | ||||||
effectiveness | Up to 90%(Online) | ||||||
Short circuit current | 82A | 137A | 205A | 273A | |||
Overload capacity | 105%-125% : 1min, 125%-150% : 30sec. | ||||||
And machine | Maximum in parallel machine 3 sets(Optional) | ||||||
Power factor | 0.9 | ||||||
Conversion time | Zero millisecond conversion | ||||||
Battery voltage*2 | 192VDC(Optional 204VDC/216VDC/228VDC/240VDC) | ||||||
Charging current *3 | 4A | 8A | 4A | 8A | |||
Battery type | Valve regulated lead-acid battery | ||||||
Standby time/min | 〉6/18 | / | 〉4/11 | / | |||
(Full load / half load) | |||||||
Communication | |||||||
Communication port*4 | RS232 | ||||||
Scalable slots | 1 pcs (Suitable for SNMP cards, ModBus-RTU cards, dry contact cards) | ||||||
Operating environment, technical specifications and standards | |||||||
Operating environment temperature and humidity | 0 to 40°C / 20%~90% | ||||||
Noise | <55dB | ||||||
Safety | IEC/EN 62040-1 | ||||||
EMC | IEC/EN 62040-2 | ||||||
Certification | TLC / radio certification / energy-saving certification | ||||||
Physical parameters | |||||||
W | 250 | 245 | 250 | 245 | 250 | ||
L | 515 | 530 | 515 | 530 | 515 | ||
H | 608 | 455 | 608 | 455 | 608 | ||
Weight(kg) | 57 | 17.5 | 65 | 20 | 26 | 34 | 34 |