20KVA DSP Online UPS power supply with isolate transformer for boiler room
GP11 series Low frequency ups 3-20KVA ups
Model:GP1103K/GP1106K/GP1110K/GP1115K/GP1120K/GP1130K/GP1140K
UPS power range: 3KVA~20KVA
Features:
-True double conversion DSP technology, high reliability
-Support 3 parallel functions,Optional N+X parallel redundancy
-Adjustable charging current,such as 8A for long-run models
-Output adjustable 200/208/220/230/240VAC
--Standard output isolation transformer.Optional input isolation transformer
-PM2.1 technology insect proof waterproof, noise and dustproof
--Excellent industrial environmental protection performance
-Dust gauze Level between IP20-IP51
-Emergency power off function(EPO)
-Eco mode operation for energy saving(ECO)
-Generator compatible
Application: Industrial environments, medical facilities, laboratory equipment, etc. are key equipment for power supply and protection.
Parameter:
Model | GP1103K | GP1106K | GP1110K | GP1115K | GP1120K | |
Capacity | 3KVA/2.4KW | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | |
INPUT | ||||||
Input Voltage range | 165VAC~275VAC | |||||
Bypass Voltage Range (Vac) | 220±15% | |||||
Mains frequency range (Hz) | 45~55Hz | |||||
Bypass frequency range (Hz) | 47~53/57~63(Hz) | |||||
Phase | Single-phase three-wire | |||||
Bypass lock function | The generator frequency is locked in 47 ~ 53Hz | |||||
Battery voltage (Vdc) | 192V(220V) | |||||
OUTPUT | ||||||
Voltage range (Vdc) | 220 ± 1%, isolated transformer output | |||||
Frequency (Hz) | 50 ± 0.5% (battery mode) | |||||
Waveform | Sine wave,THD <3% (linear load) THD <5% (non-linear load) | |||||
Switch time | ≤ 0ms (2ms between bypass and inverter) | |||||
Overload capacity | (1) 100% <load ≤110%, long-term load; (2) 110% <load ≤ 130%, 10 minutes Bypass; (3) 130% <load ≤150%, 30S bypass (4) load ≥150% 10S bypass |
|||||
output method | Wiring row | |||||
Peak coefficient | 3:01 | |||||
OTHER CHARACTERISTIC | ||||||
Display function | LCD liquid crystal display input voltage, output voltage, load size, battery voltage and so on | |||||
Alarm function | Overload, mains abnormality, battery undervoltage, battery overvoltage, UPS fault | |||||
Protective function | Battery undervoltage, overload, overtemperature, short circuit, output overvoltage, output undervoltage | |||||
Communication function (optional) | Through RS232, support power monitoring software, suitable for a variety of computer operating platform, optional SNMP network adapter to achieve power management network | |||||
Fault dry contact | Interface can be up to 2A current, easy to use, safe | |||||
Standby time | Can be configured arbitrarily | |||||
Battery efficiency | > 85% | |||||
Altitude | Meet the provisions of GB / T 7260.3-2003 | |||||
Standard | IEC 61000-4-5 Protection surge;IEC62040-1 EMC/EMI, IEC62040-1 Safety | |||||
PHYSICAL | ||||||
Dimension,D×W×H (mm) | 330*703*755 | 430*902*934 | ||||
Net Weight(KGS) | 80 | 93 | 111 | 171 | 198 | |
ENVIRONMENT | ||||||
Operating Temperature | "-10~40℃ continuous running; 45℃ derating to 85% with linear load | |||||
Humidity | 0~90% (Non-Condensing) | |||||
Noise level | less than 55dB @ 1 Meter (YD/T1095-2008) | |||||
MAINTENANCE | ||||||
Modbus RS-232/RS485 | Support Windows 2000/2003/XP/Vista/2008/7/8,Linux and MAC | |||||
Optional SNMP | Power management from SNMP manager and Web browser |