120-800KVA Three Phase Max. Protection Low Frequency Online UPS
Product snapshot:
Model: 120-800KVA
Nominal Voltage: 380/400/415VAC
Nominal frequency: 50/60Hz
Output Power Factor: 0.9
Parallel : maximum 6 pcs UPS
Indicated Language: 12 types(En. Ru. Sp. Fr...)
Efficiency Rate of Machine: ≧94% (≧98% in ECO Mode)
Specifications:
Model | 120KVA /108KW | 200KVA /180KW | 300KVA /270KW | 400KVA /360KW | 500KVA /450KW | 600KVA /540KW | 800KVA /720KW | |||||||||||||
Rated input voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||||||||||
Rated frequency | 50/60Hz | |||||||||||||||||||
Input parameters | ||||||||||||||||||||
Input voltage range | ±25%℃≤ | |||||||||||||||||||
Input frequency range | 45Hz~65Hz | |||||||||||||||||||
Input soft start function | 0-100% 5-300S settable | |||||||||||||||||||
Input power factor | >0.98(if harmonic filter is added) | |||||||||||||||||||
Input harmonic current(THDi) | <4.5%(if harmonic filter is added) | |||||||||||||||||||
bypass | ||||||||||||||||||||
Voltage range | -20%~+15% | |||||||||||||||||||
Frequency range | 50/60Hz±10% | |||||||||||||||||||
Output parameters | ||||||||||||||||||||
Output voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||||||||||
Voltage stability | ±1%(steady status), ±3%(transient status) | |||||||||||||||||||
frequency | 50/60Hz | |||||||||||||||||||
Mains power synchronization window | ±5% | |||||||||||||||||||
Actually measured frequency accuracy(internal clock) | 50/60Hz±0.05Hz | |||||||||||||||||||
Output power factor | 0.9(output 90KW per 100KVA) | |||||||||||||||||||
Transient response time | <5ms | |||||||||||||||||||
Inverter overload capacity | At 0.9 power factor, 110% fori hour, 125% for 10 minutes and 150% for 60 seconds | |||||||||||||||||||
Short circuit current form inverter | 3ph 1.5ln for 5 seconds, iph 2.9ln for 5 seconds | |||||||||||||||||||
Maximum bypass capacity | 1000% for 100ms | |||||||||||||||||||
Phase shift characteristic | With 100% balanced load : <1°; With 100% imbalanced load :<1° | |||||||||||||||||||
Total harmonic distortion(THDV) | 100% linear load: <1%; 100% non-linear load: <3% | |||||||||||||||||||
System efficiency(full load) | Up to 94%(inverter efficiency is up to 98%) | |||||||||||||||||||
Rectifier | ||||||||||||||||||||
Charger output voltage stability | 1% | |||||||||||||||||||
DC ripple voltage | ≤1% | |||||||||||||||||||
Physical parameters | ||||||||||||||||||||
Weight(kg) | 980 | 1420 | 1200 | 1750 | 1350 | 2000 | 1600 | 2200 | 2100 | 2750 | 3690 | 6390 | 7300 | |||||||
Dimension (W*D*H)mm | 900*855* 1900 | 1250*855* 1900 | 1640*855*1900 | 1250*855*1900 | 2280*855* 1900 | 2280*855*1900 | 2835*1000*1950 | 3988*1090*1950 |
Application:
Application mainly used in large IDC rooms, banks/securities settlement center, communication network management center, semi-production lines and large automation production with its control system. According to the special need of users was improved, used in large sports venues, conference room, theather, highway and railway tunnels metal halide lamp lighting system.
Key Features:
Excellent Electrical Performance:
Online double transform structure, double DSP control technology.
Unique battery protection:
Battery switch has the following characteristics:
1. Battery is isolation, safe and reliable;
2. Short circuit protection
3. In case of battery voltage causes the inverter lock, then switch off automatically to avoid battery discharge damage
4. Fitted with a remote emergency stop button, emergency stop button can be used remotely disconnect the switch; misuse protection
Efficiency, energy-saving, environmental protection design, efficiency of the machine is up to 94%
Core of high available configuration great parallel output features:
Easy installation:
■layered freestanding obturator ventilation
■ Installed against the wall
■The favourable ventilation design
■Can pass in and out the cables from the top
Operating environment:
Operating temperature range: 0~40℃
Storage temperature: -25℃~70℃
Relative humidity: 0~95%(non-condensing)
Maximum operating height: ≤elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100m
Noise(1m): 58-68db
Protection level: IP20
standard Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A
Design and Test IEC62040-3