Low Frequency Online UPS 10-600KVA
Description and Model:
High intelligence and reliable power supply UPS:
Due to its outstanding mechanical and electrical design, CNG series UPS provides maximum protection
for vital mission-critical networks, security applications (electro-medical) and industrial applications.
The load is powered continuously by the inverter with a filtered, stabilized and regulated sinewave supply.
The input and output EMI filters considerably increase the immunity of the load to mains disturbances and
surges.This series UPS uses on-line double conversion technology (VFI) with isolation transformer on the
inverter output, is supplied with Watch & Save 3000 software as standard and can be remotely monitored
using the Power NetGuard system from anywhere in the world.
Additional battery extension packs allow the standard battery runtime to be extended up to several hours.
For its convinents, it can be multi-application: Servers, Local area Network(LAN), Data centers,
Telecommunications, Electro-medical equipment and so on.
Key features:
MAXIMUM BATTERY CARE:
■ Battery deep discharge protection;
■ Temperature compensating charger;
■ Bui lt-in automatic and manual battery test feature.
MINIMUM IMPACT ON SUPPLIES EASY SOURSE;
SIMPLE TO INSTALL;
HIGH RELIABILITY;
SOME OTHER REFER:
■0.8 power factor makes CNG310/CNG330 suitable for powering ICT and Industrial loads;
■High level diagnostics: event log with 128 messages, states, measurements and alarms–available
from the bui lt-in LCD with several languages;
■BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
Specification Reference:
No. | Item | Specification |
1 | Model | 10-600KVA |
2 | Capacity | 8-600KW |
3 | Input Frequency range | 40-70Hz(Automatically select synchronization range according to grid frequency) |
4 | Input Range(HZ) | 50±5%(±10%)Bypass synchronization tracking |
5 | Output Frequency(HZ) | Normal power, tracking the frequency of power, Grid abnormal. 50±0.2% |
6 | Output Transfer time(ms) | 0 |
7 | Output Parallel operation mode parallel machine(parallel type) | 8 parallel machine |
8 | Output Crest factor | >3:1 |
9 | Index | Standard with no transfer time maintenance bypass switch |
10 | Communication function | RS232/RS485 |
11 | Panel display | LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load ,battery voltage, battery charge and discharge current, etc |
12 | Display | LCD 7" touch screen display |
13 | Operating temperature(℃) | 0~40 |
14 | Humidity | 0~95%, non-condensing |
15 | Electromagnetic compatibility | Conform GB7260.2 |
16 | Size | Depending |
17 | Weight | Depending |
Appearance:
Remark: