Centre Working Frequency(kHz): | 500KHZ±4% | Bandwidth(hz): | 20kHz |
Overall Sensitivity: | >3V | Beam Angle: | 5±1° |
2000PF±20%: | 300PF±20% | Electrostatic Capacity: | 200Ω±30% |
Operating Temperature: | -20~70℃ | Protection Class: | IP65 |
High Light: | ultrasonic flow rate sensor , high frequency ultrasonic sensor |
500KHz high frequency ultrasonic sensor for air gas flow meters flowrate measurement

Parameters
Centre working frequency (kHz) | 500KHZ±4% |
Bandwidth(hz) | 20kHz |
overall sensitivity 0 dB=3 Vp-p; cycle:8; distance:8cm (transmitter and receiver) | -65dB min |
Beam angle(-3dBfull angle) | 5±1° |
electrostatic capacity | 300PF±20% |
Minimal parallel impedance | 200Ω±30% |
Maxim operating voltage (Pulse Duty cycle ratio 2%) | <500V |
Operating temperature | -20~70℃ |
Protection class | IP65 |
Dimension

Testing curve


7 Precautions
7.1 The ceramic body of the sensor chip is mainly composed of lead zirconate titanate ceramics. Please ensure that the ceramic body complies with local environmental regulations when discarded.
7.2 The performance parameters mentioned in the specification refer to isolated components. Please fully estimate the influence of other factors when used in the whole circuit.
7.3 Sensor conductor, red is positive electrode, black is negative electrode. Pin: Long is positive, short is negative.
7.4 If you have any question about this specification, you can negotiate together.