High Frequency 108khz 16mm Ultrasonic Atomizing Transducer 1.5W Power
Medical atomization Disinfectant water atomizing 16mm 108khz Ultrasonic Atomizing Transducer
Ultrasonic Atomizing Transducer Description:
Piezoelectric ceramics are mainly used in the manufacture of ultrasonic transducers, acoustic transducers, electro-acoustic transducer, ceramic filters, ceramic transformer, ceramic frequency, high voltage generator, infrared detectors, surface acoustic wave devices, electro-optic devices, ignition and detonation devices such as piezoelectric gyroscope..
Ultrasonic Ceramic Atomizing Transducer |
The surface of the Piezo ceramic for atomizing is mainly made of 700-800 °C high-temperature sintering sealing glass glaze. It is bright and beautiful, has strong acid and alkali resistance, and its lifetime more than 5,000 hours. The Piezo ceramic for atomizing film produced by our factory has been certified by hundreds of test experiments, featuring stable performance, small fog particles, large atomization, acid and alkali corrosion resistance and long lifetime.
Ultrasonic Atomizing Transducer Specification |
1. SCOPE
This specification covers the piezoelectric ceramic transducer for wee atomization. 2. TYPE 3. SPECIFICATION
3.1 DIMENSIONS
As per the drawing No. TM-16-108KHZ
3.2 ELECTRICAL SPECIFICATION
3.2.1 Resonant Frequency (fr) fr = 108kHz±3kHz 3.2.2 Resonant Resistance (Ro)
Ro = max. 150Ω
3.2.3 Capacitance (Cp) Cp =3600pF±15% |
1. SCOPE
This specification covers the piezoelectric ceramic transducer for wee atomization.
2. TYPE
TM-16-108KHZ
3. SPECIFICATION
3.1 DIMENSIONS
As per the drawing No. TM-16-108KHZ
3.2 ELECTRICAL SPECIFICATION
3.2.1 Resonant Frequency (fr) fr = 108kHz±3kHz
3.2.2 Resonant Resistance (Ro)
Ro = max. 150Ω
Capacitance (Cp) Cp =3600pF±15%
4. TEST PROCEDURE
4.1 TEST ATMOSPHERE 23±3℃ 40 ~ 70%RH.
4.2 Fr AND Ro :
The TH-2818 Impedance Analyzer.
4.3 Cp
LCR meter at 1kHz,1Vrms
5. INPUT FOR TRANSDUCER
MAXIMUM INPUT
Voltage: 60 Vp-p 6,INPUT VOLTAGE
Input Voltage: DC3~5V
7,POWER
Max Input Power 1.5W.
(Normal use 1.5W)
8. Configuration sketch map