Vault Room Door Stainless Steel Material Door For Basement Strong Room Vault Room Door With Escape Door With Day Gate
Technical description: Our vault door complies with the American UL 608 BULLETIN-2007 "UL Safety Standard: Anti-theft vault door and template" standard requirements. The products are suitable for the financial industry, jewelry companies, insurance companies, private vaults, etc.
Basic functions: Fireproof, anti-drilling, anti-cutting, anti-impact, etc., and the protection level meets the requirements of UL standards.
Advantages:
1. Waterproof, corrosion resistance
2. Sturdy construction, wear resistance, high load bearing
3. Easy to install, supply each product an installation instruction
4.QC inspect in production, avoid any mistake 100% re-inspect before packing, double ensure all product are perfect
5.Size and color can be customized according to your requirement.
6.Professional export package to ensure safe transportation
Comliance sheet | ||
Specifications | Customers Requirments | Our Product |
Door Description | UL 608 class 2 vault door | Meet the requirments; UL 608 class 2 vault door |
Match; | 2000mmH*1000mmW(Customized) | Meet the requirments; 2000mmH*1000mmW |
Over door frame size | / | 2255mmH*1498mmW |
Wall opening size | / | 2300mmH*1650mmW |
Overall door thickness | / | 470mm |
Door thickness | Cash and other Vault Rooms (except main vaults): Vault door shall be not less than 3.5” thick, overall. Two Main Vaults at Ground Floor: Vault door shall be not less than 4.5”, overall. | Meet the requirments; 320mm |
Wall thickness | / | 320mm(minimum) |
Safe class | UL 608 class 2 | Meet the requirments; UL 608 class 2, certificate number: BP21099 |
Protection level(anti-burglary time) | 60 minutes | Meet the requirments; 60 minutes |
Protection layer thickness | / | 150mm |
Hinge | Right or left hinge | Meet the requirments; Right or left hinge |
Relocking devices | 7 independent glass relockers shall activate against any forced attempt to dislodge main locking system | Meet the requirments; 7 independent glass relockers shall activate against any forced attempt to dislodge main locking system |
Bolt Work | 7 heavy cylindrical through bolts, 2 bolts on top and 2 bolts on bottom, securing all 4 sides of door. Each bolt shall have diameter of not less than 38 mm. | Meet the requirments; 7 heavy cylindrical through bolts, 2 bolts on top and 2 bolts on bottom, securing all 4 sides of door. Each bolt shall have diameter of not less than 38 mm. |
Finish | Patinted finish | Meet the requirments; Patinted finish |
Grill gate | Patinted finish steel grill gate with two high security 5-lever mortise dead locks to provide security when the vault door is open. | Meet the requirments; Patinted finish steel grill gate with two high security 5-lever mortise dead locks to provide security when the vault door is open. |
Lock (changeable) | The Digital lock set should be meeting with VdS Class 3 or equivalent for secured vault door operation acceptable to SAMA. | Meet the requirments; UL listed; UL certificate number:BP21004 |
Lock must have redundant operation and Redundant Bass Cables with AES 256 encryption. | Meet the requirments; | |
The Data must be stored inside the locks, inside the Vault Door not in the Input unit. | Meet the requirments; | |
The Input unit must be dial type with spy proofing. | Meet the requirments; | |
The lock shall work as standalone as well as network based remotely monitored and Audit with dedicated software. | Meet the requirments; | |
Lock shall be operated with 220/240V uninterruptible power supply and re-chargeable battery pack in case of power failure. | Meet the requirments; Surelock battery management and AC power optional | |
The Input unit with keypad and LCD display shall be installed outside of the vault door replacing the mechanical locking unit. | Meet the requirments; | |
The lock shall be installed inside the vault Door on the secure side of the vault door. | Meet the requirments; | |
Each lock inside the vault door and its input unit shall be connected with special concealed security power and data cables with redundancy. Provision shall be made for future connection to Client’s central network for remote monitoring of vault operations. | Meet the requirments; | |
The main vault door and the Emergency vault door shall have separate electronics locks. | Meet the requirments; | |
Emergency door | Same lock and safe class with main door | Meet the requirments; UL 608 class 2, two (2) high quality digital locking systems; Clear size:W450mm*H500mm, Outline size:W533mm*H544mm; Emergency door weight:140KG |
Other accessories | microswitch for alarm& light control c/w wiring in the frame;Emergancy ventilator; | Meet the requirments; |
Quality assurance | Manufacturer Qualifications: Company specializing in manufacturing vault doors for at least 10 years. | Meet the requirments; 19 years experiences in manufacturing vault doors. |
TRANSPORTATION, HANDLING AND STORAGE | Deliver, store and handle vault doors in a manner to prevent damage and deterioration. | Meet the requirments; |
Provide packaging such as cardboard or other containers, separators, banding, spreaders and paper wrappings to protect all items. | Meet the requirments; | |
Store doors and frames upright, in a protected dry covered area, at least 100 mm or more above ground or floor and at least 6 mm between individual pieces. | Meet the requirments; | |
Submit a written at least 5 year warranty, starting from substantial handover of the project, for all items specified under this Section, signed by manufacturer and the contractor, against all the defects, including bowing, twisting and malfunction of locking system. | Meet the requirments; |