Applications A qualitative kit to rapidly detect human IgM and IgG antibodies against COVID-19/ SARS-CoV-2 virus in human whole blood, serum and plasma samples.
Product Features
• Simple and fast results in under 15 minutes
• Highly sensitive via visual inspection
• Tests for both IgM and IgG antibodies
• No special equipment needed
• CE IVD marked
INTENDED USE
The Test is a lateral flow immunoassay intended for the qualitative detection of nucleocapsid protein antigen from 2019-nCoV in saliva specimens directly collected from individuals who are suspected of COVID-19.
Results are for the identification of 2019-nCoV nucleocapsid protein antigen. Positive results indicate the presence of viral antigens, but clinical correlation with patient history and other diagnostic information is necessary to determine infection status. Positive results do not rule out bacterial infection or co-infection with other viruses. The agent detected may not be the definite cause of disease.
Negative results should be treated as presumptive, and do not rule out 2019-nCoV infection and should not be used as the sole basis for treatment or patient management decisions, including infection control decisions. Negative results should be considered in the context of a patient’s recent exposures, history, and the presence of clinical signs and symptoms consistent with COVID-19, and confirmed with a molecular assay.
SUMMARY AND EXPLANATION
The novel coronaviruses belong to the β genus. COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic infected people can also be an infectious source. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia and diarrhea are found in a few cases.
PRINCIPLE OF THE TEST
This test uses double-antibody sandwich to legally detect the antigen of novel coronavirus (2019-nCoV) in saliva samples. During detection, the gold labeled anti-2019-nCoV monoclonal antibody in the labeling pad binds to the 2019-nCoV antigen in the sample to form a complex, and the reaction complex moves forward along the nitrocellulose membrane under the action of chromatography, it is captured by the anti-2019-nCoV monoclonal antibody pre-coated by the detection zone (T) on the nitrocellulose membrane, and finally a red color reaction line is formed in the T zone. If the sample does not contain 2019-nCoV antigen, a red color reaction line cannot be formed in the T zone. Regardless of whether the sample to be tested contains 2019-nCoV antigen, a red reaction line will always form in the quality control area (C).
2019-nCoV IgG&IgM Antibody Rapid Test Kit
(Immunochromatography)
Catalog Number: 0524C2X001 0524C2X010
0524C2X020 0524C2X025
INTENDED USE
This Kit is an in vitro diagnostic test for the qualitative detection of IgG and IgM antibodies to the 2019-nCoV in human serum, plasma, whole blood or finger stick blood.
This product is used as a supplementary detection indicator for suspected cases with negative detection of 2019-nCoV nucleic acid or used in conjunction with nucleic acid detection in the diagnosis of suspected cases.
It cannot be used as a basis for diagnosis and exclusion of 2019-nCoV pneumonia, and is not suitable for general population screening.
A positive test result needs further confirmation. A negative test result cannot rule out the possibility of infection.
This test kit is not for the screening of donated blood.
This test kit is only provided for medical institutions
SUMMARY AND EXPLANATION
The novel coronaviruses belong to the β genus. COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the novel coronavirus are the main source of infection; asymptomatic infected people can also be an infectious source. Based on the current epidemiological investigation, the incubation period is 1 to 14 days, mostly 3 to 7 days. The main manifestations include fever, fatigue and dry cough. Nasal congestion, runny nose, sore throat, myalgia and diarrhea are found in a few cases.
PRINCIPLE
2019-nCoV IgG&IgM Antibody Rapid Test Kit is based on lateral flow immunochromatographic assay. The cassette including: 1) The recombinant novel coronavirus antigen with colloidal gold-labeled and control antibody gold marker; 2) Nitrocellulose membrane with settled two test lines (G and M) and one control line (C). M line with settled monoclonal anti-human IgM antibody; G line with settled reagent for IgG antibody test; C line with settled control antibody. When the proper specimen is added into the test device, it will be absorbed into the device by capillary action, the antibody will combine with 2019-NCOV antigen which colloidal gold-labeled if with the IgM antibody, the immune complex will be captured by the settled anti-human IgM antibody, a colored line appearing in test line(M) which means positive for IgM antibody; and if with the IgG antibody, it will be captured by the settled reagent, a colored line will appearing in test line(G) which means positive for IgG antibody. If test lines G and M without any appearance means negative result. There is a control region C in the cassette, the colored line will appear at the control line C no matter test line appeared or not. To serve as a procedure control, a colored line will appear at the Control Region(C), if the test had been performed properly
MATERIALS AND COMPONENTS
Materials provided with the test kits
Specifications
Ingredients | 1 test/Kit | 10 tests/Kit | 20 tests/Kit | 25 tests/Kit |
Test Cassette | 1 | 10 | 20 | 25 |
Sample Buffe 5ml/bottle | 1 | 1 | 1 | 1 |
Dripper | 1 | 10 | 20 | 25 |
Instructions for use | 1 | 1 | 1 | 1 |
Note: The components in different batches cannot be used interchangeably.
Materials required but not provided
STORAGE AND STABILITY
SPECIMEN COLLECTION AND PREPARATION
For fingerstick whole blood
TEST PROCEDURE
KEY TO SYMBOLS USED
![]() | Materials Included | ![]() | Test Cassette | |||
![]() | Instructions for Use | ![]() | Date of | |||
Manufacturer | ||||||
![]() | Consult Instructions | ![]() | Do Not Reuse | |||
For Use | ||||||
![]() | Store at 2°C~30°C | ![]() | Catalogue Number | |||
![]() | Expiration Date | ![]() | Keep away from Sunlight | |||
![]() | Manufacturer | ![]() | Tests per Kit | |||
![]() | Lot Number | ![]() | In Vitro Diagnostic Medical Device | |||
![]() | Keep Dry | |||||
![]() | Guangzhou Decheng Biotechnology Co., LTD | |||||
Room 218, Building 2, No.68, Nanxiang Road, Science City, Huangpu District, 510000, Guangzhou P.R.China | ||||||
TEL:+86-020-82557192 | ||||||
sales@dochekbio.com | ||||||
www.dochekbio.com | ||||||
![]() | CMC Medical Devices & Drugs S.L. | ![]() | ||||
C/ Horacio Lengo Nº 18, CP 29006, | ||||||
Málaga, Spain |