Vehicel Barrier Arm Gate Security Boom Barriers For Parking Lot Management System
Product Details:
Basic Info Of Barrier Gate:
Product Name | Vehicle barrier arm gate boom barriers for parking lot management system |
Voltage | AC220V/110V,50/60HZ |
Power Supply | 100W |
Operation Time | 1.8s/3s/6s |
Arm Type | sraight arm,fence arm,folding arm |
Arm length | 1m to 6m |
Remote Control Distance | ≥30m |
Relative Humidity | ≥90% |
Working Temperature | -40℃~+75℃ |
Net Weight | 56kgs |
MCBF | ≥5000000times |
Barrier Gate Features&Functions:
1.Manual release available if meet power failure
2.Machine core with compression spring, effectively avoids the accidents caused by spring breaking
3.Die-casting aluminum alloy motor, precision and good for thermal radiating
4.Motor cooling fan, solving the problem of heat-protection
5.Double safety limit switches (photoelectricity limit switch/motor memory sensor)
6.Reversing on obstacle
7.Traffic light interface
8.Wire control (switch signal) / Remote control
9.RS485 communication module (optional)
10.Support the Infrared Photocell for anti-bumping function (optional)
11.Support the Loop Detector for auto-closing & anti-bumping (optional)
Product Accessorirs:
No. | Name | Quantity |
1 | Car Parking Barriers | 1 |
2 | Barrier Arm | 1 |
3 | Arm Splint | 1 |
4 | Arm Fixing Bolts | 4 |
5 | Controller | 1 |
6 | Remote Controller | 2 |
7 | Hilti Bolt | 4 |
8 | Key | 2 |
9 | Specification | 1 |
Optional Accessories:
1. Loop detector: single loop detector or dual channel loop detector |
2. Photocell |
3. Flash light |
4. Boom rest/ arm holder |
5. Control board |
6. RS485 communication interface |
Shipment&Payment:
FAQ:
1) Connected power and press open/close button but barrier no action?
No. | Reason | Solution |
1 | Fuse blown | Check fuse and power in controller |
2 | Battery of remote control powered off | Change a new one |
3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box |
4 | Same frequency interference | Check photocell and loop detector |
2) Connected power and press open/close button, barrier will move but even when it is at right position, the motor still running and not stop?
No. | Reason | Solution |
1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position |
2 | Main controller failure | Change a new one |
3) Motor running but barrier arm no action?
No. | Reason | Solution |
1 | Barrier arm at 45° position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 | Tension of balancing spring not suitable | Adjust spring exactly |
3 | Low working voltage | Check the voltage and power |
4) When opening/closing, barrier arm cannot reach right position (90° vertical & 180° horizontal)?
No. | Reason | Solution |
1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90° vertical and 180° horizontal position |
Our Sevice:
1 Year Standard Warranty, excellent after-sales service;
2. 24h*7d at your service to give you best support;
3. Detailed installation manual and wiring diagram to make everything be easy;
4. If you need, we can arrange our engineer to your place to give you guide and support.